ACSizeCheck

What size AC for Greenwood, SC? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Greenwood needs

3.5 tons central AC or heat pump, about 36,900 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.1 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 651 square feet in this climate. For a single room, size by the room: 18.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Greenwood County Airport (4 mi away). Jul is the hottest month, averaging a high of 90.2°F and a low of 68.5°F, with about 60 days a year at 90°F or more. That gives a design temperature of 96°F against 75°F inside.

What it costs to run

About 2,471 kWh a year at SEER2 14.3, or roughly $393 at South Carolina's average residential rate of 15.9¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Greenwood

Of the 36,900 BTU/hr, 15,120 comes through walls, roof and windows on a 96°F afternoon (41%), 13,000 is sun on the house (35%), 2,120 is four people and their appliances, and 6,700 is moisture the coil has to wring out of Greenwood's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 30,240 BTU/hr before the moisture allowance.

Other house sizes in Greenwood

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft19,7001.5 tons2 tons
1,500 sq ft28,3002.5 tons2.5 tons
2,500 sq ft45,5004 tons5 tons
3,000 sq ft54,0005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,800 BTU/hr; a 350 sq ft living room needs about 6,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,000 BTU/hr.

Month by month in Greenwood

MonthAvg highCooling degree daysAC kWh
Jan53.4°F00
Feb57.3°F12
Mar65°F913
Apr73.4°F4363
May80.5°F155228
Jun86.8°F330486
Jul90.2°F445656
Aug88.7°F408601
Sep83.2°F235346
Oct73.5°F4566
Nov63.2°F46
Dec55.5°F11

Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 958 hours a year at full output.

Greenwood against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Newberry, SC32 mi98°F3.5 tons
Fountain Inn, SC35 mi96°F3.5 tons
Anderson, SC36 mi96°F3.5 tons
Simpsonville, SC37 mi97°F3.5 tons
Mauldin, SC41 mi97°F3.5 tons
Greenville, SC46 mi97°F3.5 tons

Of 42 South Carolina cities here, Greenwood has the 33rd highest cooling load. The range runs from Gaffney at 32,300 BTU/hr to Columbia at 43,100.

Where Greenwood's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Greenwood County Airport, 4 miles from the center of Greenwood at 617 ft above sea level. That is close enough that the station's summers are Greenwood's summers.

No other city in this set uses Greenwood County Airport, so this sizing is Greenwood's alone.

The sun over Greenwood in late July

At 34.20°N, the noon sun on 21 July stands 76.2° above the horizon over Greenwood and the day runs 13 h 57 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

22,667 people live in Greenwood, the 25th largest of the 42 South Carolina cities sized on this site. Coordinates used: 34.1954, -82.1537.

Greenwood AC sizing questions

What size AC does a 2,000 sq ft house in Greenwood, SC need?

About 3.5 tons, for a cooling load of 36,900 BTU/hr on a 96°F design day. That is one ton per 651 square feet in Greenwood's climate.

Is 20 BTU per square foot right for Greenwood?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Greenwood County Airport. For a single room here, plan on 18.4 BTU/hr per square foot.

What does central AC cost to run in Greenwood?

About $393 a year: 2,471 kWh at SEER2 14.3 and 15.9¢ per kWh, over 5 cooling months.