What size AC for Newberg, OR? 2 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Newberg needs
2 tons central AC or heat pump, about 25,500 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 65% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 943 square feet in this climate. For a single room, size by the room: 12.7 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Aurora State Airport (10.1 mi away). Aug is the hottest month, averaging a high of 83.3°F and a low of 56.3°F, with about 18 days a year at 90°F or more. That gives a design temperature of 88°F against 75°F inside.
What it costs to run
About 571 kWh a year at SEER2 14.3, or roughly $88 at Oregon's average residential rate of 15.46¢ per kWh. Cooling runs 3 months of the year here.
What drives the load in Newberg
Of the 25,500 BTU/hr, 9,360 comes through walls, roof and windows on a 88°F afternoon (37%), 13,000 is sun on the house (51%), 2,120 is four people and their appliances, and 1,000 is moisture the coil has to wring out of Newberg's summer air (4%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 24,480 BTU/hr before the moisture allowance.
Other house sizes in Newberg
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 13,800 | 1.5 tons | 2 tons |
| 1,500 sq ft | 19,600 | 1.5 tons | 2.5 tons |
| 2,500 sq ft | 31,300 | 2.5 tons | 5 tons |
| 3,000 sq ft | 37,100 | 3.5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,600 BTU/hr.
Month by month in Newberg
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 48.5°F | 0 | 0 |
| Feb | 52.5°F | 0 | 0 |
| Mar | 57.1°F | 0 | 0 |
| Apr | 62°F | 2 | 3 |
| May | 69.2°F | 20 | 25 |
| Jun | 74.5°F | 48 | 60 |
| Jul | 83.1°F | 156 | 196 |
| Aug | 83.3°F | 161 | 202 |
| Sep | 77.4°F | 65 | 81 |
| Oct | 64.3°F | 4 | 5 |
| Nov | 53.7°F | 0 | 0 |
| Dec | 47.6°F | 0 | 0 |
Aug alone uses 35% of the year's cooling energy. The unit runs the equivalent of 321 hours a year at full output.
Newberg against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Sherwood, OR | 7 mi | 88°F | 2 tons |
| Wilsonville, OR | 9 mi | 88°F | 2 tons |
| Tualatin, OR | 10 mi | 88°F | 2 tons |
| Tigard, OR | 12 mi | 87°F | 2 tons |
| Woodburn, OR | 12 mi | 88°F | 2 tons |
| McMinnville, OR | 13 mi | 88°F | 2 tons |
Of 57 Oregon cities here, Newberg has the 28th highest cooling load. The range runs from North Bend at 15,700 BTU/hr to Ontario at 36,500.
Where Newberg's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Aurora State Airport, 10.1 miles from the center of Newberg at 196 ft above sea level. That is close enough that the station's summers are Newberg's summers.
10 other cities use the same station and get the same climate inputs. The closest to Newberg: Sherwood (7 mi away, 8.5 mi from the station), Wilsonville (9 mi away, 4.5 mi from the station), Tualatin (10 mi away, 9 mi from the station), Woodburn (12 mi away, 8.2 mi from the station), Canby (14 mi away, 4.2 mi from the station). Newberg is farther from the station than 5 of them.
The sun over Newberg in late July
At 45.31°N, the noon sun on 21 July stands 65.1° above the horizon over Newberg and the day runs 14 h 57 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
27,136 people live in Newberg, the 23rd largest of the 57 Oregon cities sized on this site. Coordinates used: 45.3073, -122.9602.
Newberg AC sizing questions
What size AC does a 2,000 sq ft house in Newberg, OR need?
About 2 tons, for a cooling load of 25,500 BTU/hr on a 88°F design day. That is one ton per 943 square feet in Newberg's climate.
Is 20 BTU per square foot right for Newberg?
The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Aurora State Airport. For a single room here, plan on 12.7 BTU/hr per square foot.
What does central AC cost to run in Newberg?
About $88 a year: 571 kWh at SEER2 14.3 and 15.46¢ per kWh, over 3 cooling months.