ACSizeCheck

What size AC for Canby, OR? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Canby needs

2 tons central AC or heat pump, about 25,500 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 65% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 943 square feet in this climate. For a single room, size by the room: 12.7 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Aurora State Airport (4.2 mi away). Aug is the hottest month, averaging a high of 83.3°F and a low of 56.3°F, with about 18 days a year at 90°F or more. That gives a design temperature of 88°F against 75°F inside.

What it costs to run

About 571 kWh a year at SEER2 14.3, or roughly $88 at Oregon's average residential rate of 15.46¢ per kWh. Cooling runs 3 months of the year here.

What drives the load in Canby

Of the 25,500 BTU/hr, 9,360 comes through walls, roof and windows on a 88°F afternoon (37%), 13,000 is sun on the house (51%), 2,120 is four people and their appliances, and 1,000 is moisture the coil has to wring out of Canby's summer air (4%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 24,480 BTU/hr before the moisture allowance.

Other house sizes in Canby

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft13,8001.5 tons2 tons
1,500 sq ft19,6001.5 tons2.5 tons
2,500 sq ft31,3002.5 tons5 tons
3,000 sq ft37,1003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,600 BTU/hr.

Month by month in Canby

MonthAvg highCooling degree daysAC kWh
Jan48.5°F00
Feb52.5°F00
Mar57.1°F00
Apr62°F23
May69.2°F2025
Jun74.5°F4860
Jul83.1°F156196
Aug83.3°F161202
Sep77.4°F6581
Oct64.3°F45
Nov53.7°F00
Dec47.6°F00

Aug alone uses 35% of the year's cooling energy. The unit runs the equivalent of 321 hours a year at full output.

Canby against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Wilsonville, OR5 mi88°F2 tons
Oregon City, OR7 mi88°F2 tons
West Linn, OR7 mi88°F2 tons
Tualatin, OR9 mi88°F2 tons
Molalla, OR9 mi88°F2 tons
Gladstone, OR10 mi88°F2 tons

Of 57 Oregon cities here, Canby has the 31st highest cooling load. The range runs from North Bend at 15,700 BTU/hr to Ontario at 36,500.

Where Canby's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Aurora State Airport, 4.2 miles from the center of Canby at 196 ft above sea level. That is close enough that the station's summers are Canby's summers.

10 other cities use the same station and get the same climate inputs. The closest to Canby: Wilsonville (5 mi away, 4.5 mi from the station), Oregon City (7 mi away, 10.9 mi from the station), West Linn (7 mi away, 10.5 mi from the station), Tualatin (9 mi away, 9 mi from the station), Molalla (9 mi away, 11.3 mi from the station). Canby sits closer to the station than any of them, so its numbers are the best measured of the group.

The sun over Canby in late July

At 45.27°N, the noon sun on 21 July stands 65.1° above the horizon over Canby and the day runs 14 h 56 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

18,027 people live in Canby, the 34th largest of the 57 Oregon cities sized on this site. Coordinates used: 45.2651, -122.6884.

Canby AC sizing questions

What size AC does a 2,000 sq ft house in Canby, OR need?

About 2 tons, for a cooling load of 25,500 BTU/hr on a 88°F design day. That is one ton per 943 square feet in Canby's climate.

Is 20 BTU per square foot right for Canby?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Aurora State Airport. For a single room here, plan on 12.7 BTU/hr per square foot.

What does central AC cost to run in Canby?

About $88 a year: 571 kWh at SEER2 14.3 and 15.46¢ per kWh, over 3 cooling months.