ACSizeCheck

What size AC for Naugatuck, CT? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Naugatuck needs

2.5 tons central AC or heat pump, about 26,400 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 59% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 908 square feet in this climate. For a single room, size by the room: 13.2 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Meriden Markham Municipal Airport (11.7 mi away). Jul is the hottest month, averaging a high of 84°F and a low of 62.5°F, with about 15 days a year at 90°F or more. That gives a design temperature of 88°F against 75°F inside.

What it costs to run

About 937 kWh a year at SEER2 14.3, or roughly $258 at Connecticut's average residential rate of 27.47¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Naugatuck

Of the 26,400 BTU/hr, 9,360 comes through walls, roof and windows on a 88°F afternoon (35%), 13,000 is sun on the house (49%), 2,120 is four people and their appliances, and 2,000 is moisture the coil has to wring out of Naugatuck's summer air (8%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 24,480 BTU/hr before the moisture allowance.

Other house sizes in Naugatuck

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,4001.5 tons2 tons
1,500 sq ft20,4002 tons2.5 tons
2,500 sq ft32,5003 tons5 tons
3,000 sq ft38,5003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,900 BTU/hr.

Month by month in Naugatuck

MonthAvg highCooling degree daysAC kWh
Jan37°F00
Feb39.1°F00
Mar47.5°F00
Apr59.9°F45
May70.4°F2837
Jun78.7°F126164
Jul84°F259338
Aug82.4°F216282
Sep75.4°F78101
Oct63.6°F810
Nov52°F00
Dec41.7°F00

Jul alone uses 36% of the year's cooling energy. The unit runs the equivalent of 507 hours a year at full output.

Naugatuck against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Waterbury, CT5 mi88°F2.5 tons
Ansonia, CT10 mi86°F2.5 tons
Derby, CT11 mi86°F2.5 tons
Shelton, CT13 mi88°F2.5 tons
Meriden, CT14 mi88°F2.5 tons
New Haven, CT14 mi86°F2.5 tons

Of 21 Connecticut cities here, Naugatuck has the 16th highest cooling load. The range runs from Groton at 24,800 BTU/hr to Hartford at 29,000.

Where Naugatuck's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Meriden Markham Municipal Airport, 11.7 miles from the center of Naugatuck at 97 ft above sea level. That is close enough that the station's summers are Naugatuck's summers.

4 other cities use the same station and get the same climate inputs. The closest to Naugatuck: Waterbury (5 mi away, 11.3 mi from the station), Meriden (14 mi away, 2.5 mi from the station), Bristol (15 mi away, 13.2 mi from the station), Middletown (21 mi away, 9.2 mi from the station). Naugatuck is farther from the station than 3 of them.

The sun over Naugatuck in late July

At 41.49°N, the noon sun on 21 July stands 68.9° above the horizon over Naugatuck and the day runs 14 h 34 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

32,116 people live in Naugatuck, the 17th largest of the 21 Connecticut cities sized on this site. Coordinates used: 41.4878, -73.0516.

Naugatuck AC sizing questions

What size AC does a 2,000 sq ft house in Naugatuck, CT need?

About 2.5 tons, for a cooling load of 26,400 BTU/hr on a 88°F design day. That is one ton per 908 square feet in Naugatuck's climate.

Is 20 BTU per square foot right for Naugatuck?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Meriden Markham Municipal Airport. For a single room here, plan on 13.2 BTU/hr per square foot.

What does central AC cost to run in Naugatuck?

About $258 a year: 937 kWh at SEER2 14.3 and 27.47¢ per kWh, over 4 cooling months.