ACSizeCheck

What size AC for Ansonia, CT? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Ansonia needs

2.5 tons central AC or heat pump, about 26,500 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 59% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 906 square feet in this climate. For a single room, size by the room: 13.2 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at New Haven Tweed Airport (11.1 mi away). Jul is the hottest month, averaging a high of 82.1°F and a low of 65.7°F, with about 6 days a year at 90°F or more. That gives a design temperature of 86°F against 75°F inside.

What it costs to run

About 1,063 kWh a year at SEER2 14.3, or roughly $292 at Connecticut's average residential rate of 27.47¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Ansonia

Of the 26,500 BTU/hr, 7,920 comes through walls, roof and windows on a 86°F afternoon (30%), 13,000 is sun on the house (49%), 2,120 is four people and their appliances, and 3,500 is moisture the coil has to wring out of Ansonia's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,040 BTU/hr before the moisture allowance.

Other house sizes in Ansonia

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,5001.5 tons2 tons
1,500 sq ft20,5002 tons2.5 tons
2,500 sq ft32,5003 tons5 tons
3,000 sq ft38,5003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,900 BTU/hr.

Month by month in Ansonia

MonthAvg highCooling degree daysAC kWh
Jan38.1°F00
Feb40.2°F00
Mar47°F00
Apr57.8°F11
May67.7°F1521
Jun76.4°F121169
Jul82.1°F277385
Aug81°F246342
Sep74.7°F93130
Oct63.8°F1014
Nov53.4°F00
Dec43.7°F00

Jul alone uses 36% of the year's cooling energy. The unit runs the equivalent of 573 hours a year at full output.

Ansonia against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Derby, CT1 mi86°F2.5 tons
Shelton, CT5 mi88°F2.5 tons
West Haven, CT7 mi86°F2.5 tons
New Haven, CT8 mi86°F2.5 tons
Milford, CT8 mi88°F2.5 tons
Naugatuck, CT10 mi88°F2.5 tons

Of 21 Connecticut cities here, Ansonia has the 10th highest cooling load. The range runs from Groton at 24,800 BTU/hr to Hartford at 29,000.

Where Ansonia's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is New Haven Tweed Airport, 11.1 miles from the center of Ansonia at 6 ft above sea level. That is close enough that the station's summers are Ansonia's summers.

3 other cities use the same station and get the same climate inputs. The closest to Ansonia: Derby (1 mi away, 11.1 mi from the station), West Haven (7 mi away, 4.2 mi from the station), New Haven (8 mi away, 4 mi from the station). Ansonia is farther from the station than 2 of them.

The sun over Ansonia in late July

At 41.34°N, the noon sun on 21 July stands 69.1° above the horizon over Ansonia and the day runs 14 h 33 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

19,195 people live in Ansonia, the 19th largest of the 21 Connecticut cities sized on this site. Coordinates used: 41.3442, -73.0698.

Ansonia AC sizing questions

What size AC does a 2,000 sq ft house in Ansonia, CT need?

About 2.5 tons, for a cooling load of 26,500 BTU/hr on a 86°F design day. That is one ton per 906 square feet in Ansonia's climate.

Is 20 BTU per square foot right for Ansonia?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at New Haven Tweed Airport. For a single room here, plan on 13.2 BTU/hr per square foot.

What does central AC cost to run in Ansonia?

About $292 a year: 1,063 kWh at SEER2 14.3 and 27.47¢ per kWh, over 4 cooling months.