ACSizeCheck

What size AC for Nacogdoches, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Nacogdoches needs

4 tons central AC or heat pump, about 44,000 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.7 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 546 square feet in this climate. For a single room, size by the room: 22 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Nacogdoches (0.6 mi away). Aug is the hottest month, averaging a high of 93.3°F and a low of 73.1°F, with about 98 days a year at 90°F or more. That gives a design temperature of 101°F against 75°F inside.

What it costs to run

About 3,960 kWh a year at SEER2 14.3, or roughly $635 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Nacogdoches

Of the 44,000 BTU/hr, 18,720 comes through walls, roof and windows on a 101°F afternoon (43%), 13,000 is sun on the house (30%), 2,120 is four people and their appliances, and 10,200 is moisture the coil has to wring out of Nacogdoches's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,840 BTU/hr before the moisture allowance.

Other house sizes in Nacogdoches

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft23,4002 tons2 tons
1,500 sq ft33,7003 tons2.5 tons
2,500 sq ft54,3005 tons5 tons
3,000 sq ft64,6005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,300 BTU/hr; a 350 sq ft living room needs about 7,700 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 13,200 BTU/hr.

Month by month in Nacogdoches

MonthAvg highCooling degree daysAC kWh
Jan57.7°F47
Feb62.3°F914
Mar69.3°F3047
Apr76.3°F89139
May82.8°F266418
Jun89°F456716
Jul92.6°F563884
Aug93.3°F564886
Sep87.8°F374587
Oct78.2°F135212
Nov67.8°F2641
Dec59.5°F610

Aug alone uses 22% of the year's cooling energy. The unit runs the equivalent of 1,287 hours a year at full output.

Nacogdoches against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Lufkin, TX21 mi101°F3.5 tons
Henderson, TX39 mi101°F3.5 tons
Jacksonville, TX43 mi102°F4 tons
Kilgore, TX56 mi102°F4 tons
Palestine, TX59 mi102°F4 tons
Tyler, TX62 mi102°F4 tons

Of 252 Texas cities here, Nacogdoches has the 187th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Nacogdoches's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Nacogdoches, 0.6 miles from the center of Nacogdoches at 435 ft above sea level. That is close enough that the station's summers are Nacogdoches's summers.

No other city in this set uses Nacogdoches, so this sizing is Nacogdoches's alone.

The sun over Nacogdoches in late July

At 31.61°N, the noon sun on 21 July stands 78.8° above the horizon over Nacogdoches and the day runs 13 h 46 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

32,381 people live in Nacogdoches, the 112th largest of the 252 Texas cities sized on this site. Coordinates used: 31.6124, -94.6520.

Nacogdoches AC sizing questions

What size AC does a 2,000 sq ft house in Nacogdoches, TX need?

About 4 tons, for a cooling load of 44,000 BTU/hr on a 101°F design day. That is one ton per 546 square feet in Nacogdoches's climate.

Is 20 BTU per square foot right for Nacogdoches?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Nacogdoches. For a single room here, plan on 22 BTU/hr per square foot.

What does central AC cost to run in Nacogdoches?

About $635 a year: 3,960 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.