ACSizeCheck

What size AC for Mount Vernon, OH? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Mount Vernon needs

2 tons central AC or heat pump, about 24,900 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 69% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 965 square feet in this climate. For a single room, size by the room: 12.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Fredericktown 4 S (3.8 mi away). Jul is the hottest month, averaging a high of 81.9°F and a low of 58.7°F, with about 7 days a year at 90°F or more. That gives a design temperature of 86°F against 75°F inside.

What it costs to run

About 675 kWh a year at SEER2 14.3, or roughly $127 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 3 months of the year here.

What drives the load in Mount Vernon

Of the 24,900 BTU/hr, 7,920 comes through walls, roof and windows on a 86°F afternoon (32%), 13,000 is sun on the house (52%), 2,120 is four people and their appliances, and 1,800 is moisture the coil has to wring out of Mount Vernon's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,040 BTU/hr before the moisture allowance.

Other house sizes in Mount Vernon

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft13,6001.5 tons2 tons
1,500 sq ft19,2001.5 tons2.5 tons
2,500 sq ft30,5002.5 tons5 tons
3,000 sq ft36,2003 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,400 BTU/hr.

Month by month in Mount Vernon

MonthAvg highCooling degree daysAC kWh
Jan33.1°F00
Feb36.8°F00
Mar47.1°F00
Apr60.5°F56
May70.7°F3546
Jun78.5°F122160
Jul81.9°F178233
Aug80.2°F133174
Sep74.4°F3951
Oct63.1°F45
Nov49.4°F00
Dec38.3°F00

Jul alone uses 35% of the year's cooling energy. The unit runs the equivalent of 388 hours a year at full output.

Mount Vernon against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Newark, OH22 mi91°F2.5 tons
Heath, OH25 mi91°F2.5 tons
New Albany, OH26 mi90°F2.5 tons
Mansfield, OH27 mi87°F2 tons
Pataskala, OH28 mi90°F2.5 tons
Galion, OH29 mi87°F2 tons

Of 176 Ohio cities here, Mount Vernon has the 172nd highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.

Where Mount Vernon's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Fredericktown 4 S, 3.8 miles from the center of Mount Vernon at 1,050 ft above sea level. That is close enough that the station's summers are Mount Vernon's summers.

No other city in this set uses Fredericktown 4 S, so this sizing is Mount Vernon's alone.

The sun over Mount Vernon in late July

At 40.39°N, the noon sun on 21 July stands 70.0° above the horizon over Mount Vernon and the day runs 14 h 28 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

17,329 people live in Mount Vernon, the 110th largest of the 176 Ohio cities sized on this site. Coordinates used: 40.3852, -82.4749.

Mount Vernon AC sizing questions

What size AC does a 2,000 sq ft house in Mount Vernon, OH need?

About 2 tons, for a cooling load of 24,900 BTU/hr on a 86°F design day. That is one ton per 965 square feet in Mount Vernon's climate.

Is 20 BTU per square foot right for Mount Vernon?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Fredericktown 4 S. For a single room here, plan on 12.4 BTU/hr per square foot.

What does central AC cost to run in Mount Vernon?

About $127 a year: 675 kWh at SEER2 14.3 and 18.81¢ per kWh, over 3 cooling months.