ACSizeCheck

What size AC for Medina, OH? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Medina needs

2 tons central AC or heat pump, about 25,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 64% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 935 square feet in this climate. For a single room, size by the room: 12.8 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Wooster Wayne County Airport (18.1 mi away). Jul is the hottest month, averaging a high of 82.4°F and a low of 60.5°F, with about 7 days a year at 90°F or more. That gives a design temperature of 87°F against 75°F inside.

What it costs to run

About 771 kWh a year at SEER2 14.3, or roughly $145 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 3 months of the year here.

What drives the load in Medina

Of the 25,700 BTU/hr, 8,640 comes through walls, roof and windows on a 87°F afternoon (34%), 13,000 is sun on the house (51%), 2,120 is four people and their appliances, and 1,900 is moisture the coil has to wring out of Medina's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,760 BTU/hr before the moisture allowance.

Other house sizes in Medina

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,0001.5 tons2 tons
1,500 sq ft19,8001.5 tons2.5 tons
2,500 sq ft31,5003 tons5 tons
3,000 sq ft37,3003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,700 BTU/hr.

Month by month in Medina

MonthAvg highCooling degree daysAC kWh
Jan33.9°F00
Feb36.8°F00
Mar46.6°F11
Apr60°F45
May70.9°F4154
Jun78.8°F135176
Jul82.4°F207269
Aug80.2°F146190
Sep74.4°F4964
Oct63°F811
Nov49.3°F00
Dec38.4°F00

Jul alone uses 35% of the year's cooling energy. The unit runs the equivalent of 430 hours a year at full output.

Medina against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Brunswick, OH8 mi88°F2.5 tons
Wadsworth, OH10 mi87°F2 tons
Strongsville, OH12 mi88°F2.5 tons
Norton, OH14 mi90°F2.5 tons
North Royalton, OH14 mi88°F2.5 tons
Broadview Heights, OH16 mi88°F2.5 tons

Of 176 Ohio cities here, Medina has the 143rd highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.

Where Medina's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Wooster Wayne County Airport, 18.1 miles from the center of Medina at 1,105 ft above sea level. That is close enough that the station's summers are Medina's summers.

1 other city uses the same station and get the same climate inputs. The closest to Medina: Wadsworth (10 mi away, 13.4 mi from the station). Medina is farther from the station than 1 of them.

The sun over Medina in late July

At 41.13°N, the noon sun on 21 July stands 69.3° above the horizon over Medina and the day runs 14 h 32 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

25,757 people live in Medina, the 61st largest of the 176 Ohio cities sized on this site. Coordinates used: 41.1346, -81.8695.

Medina AC sizing questions

What size AC does a 2,000 sq ft house in Medina, OH need?

About 2 tons, for a cooling load of 25,700 BTU/hr on a 87°F design day. That is one ton per 935 square feet in Medina's climate.

Is 20 BTU per square foot right for Medina?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Wooster Wayne County Airport. For a single room here, plan on 12.8 BTU/hr per square foot.

What does central AC cost to run in Medina?

About $145 a year: 771 kWh at SEER2 14.3 and 18.81¢ per kWh, over 3 cooling months.