ACSizeCheck

What size AC for North Royalton, OH? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in North Royalton needs

2.5 tons central AC or heat pump, about 28,200 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 49% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 853 square feet in this climate. For a single room, size by the room: 14.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Cleveland (8.9 mi away). Jul is the hottest month, averaging a high of 83.7°F and a low of 65.3°F, with about 12 days a year at 90°F or more. That gives a design temperature of 88°F against 75°F inside.

What it costs to run

About 1,316 kWh a year at SEER2 14.3, or roughly $248 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in North Royalton

Of the 28,200 BTU/hr, 9,360 comes through walls, roof and windows on a 88°F afternoon (33%), 13,000 is sun on the house (46%), 2,120 is four people and their appliances, and 3,700 is moisture the coil has to wring out of North Royalton's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 24,480 BTU/hr before the moisture allowance.

Other house sizes in North Royalton

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft15,3001.5 tons2 tons
1,500 sq ft21,7002 tons2.5 tons
2,500 sq ft34,6003 tons5 tons
3,000 sq ft41,0003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,100 BTU/hr; a 350 sq ft living room needs about 4,900 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,500 BTU/hr.

Month by month in North Royalton

MonthAvg highCooling degree daysAC kWh
Jan35.8°F00
Feb38.5°F00
Mar47.1°F23
Apr60.1°F1014
May71.1°F6691
Jun79.8°F193268
Jul83.7°F296412
Aug82°F251349
Sep75.6°F110153
Oct63.7°F1826
Nov51.3°F11
Dec40.4°F00

Jul alone uses 31% of the year's cooling energy. The unit runs the equivalent of 669 hours a year at full output.

North Royalton against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Broadview Heights, OH4 mi88°F2.5 tons
Strongsville, OH4 mi88°F2.5 tons
Parma Heights, OH5 mi88°F2.5 tons
Parma, OH5 mi88°F2.5 tons
Middleburg Heights, OH5 mi88°F2.5 tons
Seven Hills, OH6 mi88°F2.5 tons

Of 176 Ohio cities here, North Royalton has the 89th highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.

Where North Royalton's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Cleveland, 8.9 miles from the center of North Royalton at 860 ft above sea level. That is close enough that the station's summers are North Royalton's summers.

19 other cities use the same station and get the same climate inputs. The closest to North Royalton: Broadview Heights (4 mi away, 11.4 mi from the station), Strongsville (4 mi away, 7.1 mi from the station), Parma Heights (5 mi away, 5.5 mi from the station), Parma (5 mi away, 7.1 mi from the station), Middleburg Heights (5 mi away, 3.8 mi from the station). North Royalton is farther from the station than 14 of them.

The sun over North Royalton in late July

At 41.32°N, the noon sun on 21 July stands 69.1° above the horizon over North Royalton and the day runs 14 h 33 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

30,894 people live in North Royalton, the 48th largest of the 176 Ohio cities sized on this site. Coordinates used: 41.3159, -81.7481.

North Royalton AC sizing questions

What size AC does a 2,000 sq ft house in North Royalton, OH need?

About 2.5 tons, for a cooling load of 28,200 BTU/hr on a 88°F design day. That is one ton per 853 square feet in North Royalton's climate.

Is 20 BTU per square foot right for North Royalton?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Cleveland. For a single room here, plan on 14.1 BTU/hr per square foot.

What does central AC cost to run in North Royalton?

About $248 a year: 1,316 kWh at SEER2 14.3 and 18.81¢ per kWh, over 5 cooling months.