ACSizeCheck

What size AC for LaGrange, GA? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in LaGrange needs

3.5 tons central AC or heat pump, about 37,800 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.1 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 635 square feet in this climate. For a single room, size by the room: 18.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at La Grange 1n (1.9 mi away). Jul is the hottest month, averaging a high of 90.7°F and a low of 68.9°F, with about 55 days a year at 90°F or more. That gives a design temperature of 97°F against 75°F inside.

What it costs to run

About 2,724 kWh a year at SEER2 14.3, or roughly $422 at Georgia's average residential rate of 15.48¢ per kWh. Cooling runs 6 months of the year here.

What drives the load in LaGrange

Of the 37,800 BTU/hr, 15,840 comes through walls, roof and windows on a 97°F afternoon (42%), 13,000 is sun on the house (34%), 2,120 is four people and their appliances, and 6,800 is moisture the coil has to wring out of LaGrange's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 30,960 BTU/hr before the moisture allowance.

Other house sizes in LaGrange

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft20,2002 tons2 tons
1,500 sq ft29,0002.5 tons2.5 tons
2,500 sq ft46,6004 tons5 tons
3,000 sq ft55,4005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,800 BTU/hr; a 350 sq ft living room needs about 6,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,300 BTU/hr.

Month by month in LaGrange

MonthAvg highCooling degree daysAC kWh
Jan56.2°F11
Feb60.2°F12
Mar69°F1624
Apr76.2°F4973
May82.8°F186274
Jun88.3°F365538
Jul90.7°F459676
Aug89.9°F438646
Sep84.7°F259382
Oct75.6°F6697
Nov66.2°F710
Dec57.6°F12

Jul alone uses 25% of the year's cooling energy. The unit runs the equivalent of 1,031 hours a year at full output.

LaGrange against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Valley, AL17 mi96°F3.5 tons
Newnan, GA28 mi97°F3.5 tons
Opelika, AL32 mi95°F3 tons
Columbus, GA37 mi100°F4 tons
Peachtree City, GA37 mi97°F3.5 tons
Carrollton, GA38 mi95°F3 tons

Of 101 Georgia cities here, LaGrange has the 31st highest cooling load. The range runs from Cumming at 33,100 BTU/hr to Albany at 44,000.

Where LaGrange's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is La Grange 1n, 1.9 miles from the center of LaGrange at 730 ft above sea level. That is close enough that the station's summers are LaGrange's summers.

No other city in this set uses La Grange 1n, so this sizing is LaGrange's alone.

The sun over LaGrange in late July

At 33.03°N, the noon sun on 21 July stands 77.4° above the horizon over LaGrange and the day runs 13 h 52 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

33,564 people live in LaGrange, the 37th largest of the 101 Georgia cities sized on this site. Coordinates used: 33.0270, -85.0383.

LaGrange AC sizing questions

What size AC does a 2,000 sq ft house in LaGrange, GA need?

About 3.5 tons, for a cooling load of 37,800 BTU/hr on a 97°F design day. That is one ton per 635 square feet in LaGrange's climate.

Is 20 BTU per square foot right for LaGrange?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at La Grange 1n. For a single room here, plan on 18.9 BTU/hr per square foot.

What does central AC cost to run in LaGrange?

About $422 a year: 2,724 kWh at SEER2 14.3 and 15.48¢ per kWh, over 6 cooling months.