ACSizeCheck

What size AC for Jackson, TN? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Jackson needs

3.5 tons central AC or heat pump, about 36,900 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.1 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 651 square feet in this climate. For a single room, size by the room: 18.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Jackson Mckellar- Sipes Airport (6.3 mi away). Jul is the hottest month, averaging a high of 90°F and a low of 69°F, with about 58 days a year at 90°F or more. That gives a design temperature of 96°F against 75°F inside.

What it costs to run

About 2,531 kWh a year at SEER2 14.3, or roughly $349 at Tennessee's average residential rate of 13.8¢ per kWh. Cooling runs 6 months of the year here.

What drives the load in Jackson

Of the 36,900 BTU/hr, 15,120 comes through walls, roof and windows on a 96°F afternoon (41%), 13,000 is sun on the house (35%), 2,120 is four people and their appliances, and 6,700 is moisture the coil has to wring out of Jackson's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 30,240 BTU/hr before the moisture allowance.

Other house sizes in Jackson

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft19,7001.5 tons2 tons
1,500 sq ft28,3002.5 tons2.5 tons
2,500 sq ft45,5004 tons5 tons
3,000 sq ft54,0005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,800 BTU/hr; a 350 sq ft living room needs about 6,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,000 BTU/hr.

Month by month in Jackson

MonthAvg highCooling degree daysAC kWh
Jan48.7°F00
Feb53°F12
Mar62.2°F1015
Apr72.1°F5073
May80°F168248
Jun87.1°F343506
Jul90°F449663
Aug89.5°F412608
Sep83.9°F223328
Oct73.3°F5480
Nov60.8°F58
Dec51.4°F11

Jul alone uses 26% of the year's cooling energy. The unit runs the equivalent of 981 hours a year at full output.

Jackson against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Dyersburg, TN40 mi96°F3.5 tons
Martin, TN47 mi96°F3.5 tons
Oakland, TN49 mi98°F3.5 tons
Corinth, MS52 mi96°F3.5 tons
Paris, TN53 mi93°F3 tons
Arlington, TN54 mi98°F3.5 tons

Of 65 Tennessee cities here, Jackson has the 20th highest cooling load. The range runs from Crossville at 27,300 BTU/hr to Memphis at 41,200.

Where Jackson's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Jackson Mckellar- Sipes Airport, 6.3 miles from the center of Jackson at 424 ft above sea level. That is close enough that the station's summers are Jackson's summers.

No other city in this set uses Jackson Mckellar- Sipes Airport, so this sizing is Jackson's alone.

The sun over Jackson in late July

At 35.66°N, the noon sun on 21 July stands 74.7° above the horizon over Jackson and the day runs 14 h 04 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

69,303 people live in Jackson, the 9th largest of the 65 Tennessee cities sized on this site. Coordinates used: 35.6585, -88.8374.

Jackson AC sizing questions

What size AC does a 2,000 sq ft house in Jackson, TN need?

About 3.5 tons, for a cooling load of 36,900 BTU/hr on a 96°F design day. That is one ton per 651 square feet in Jackson's climate.

Is 20 BTU per square foot right for Jackson?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Jackson Mckellar- Sipes Airport. For a single room here, plan on 18.4 BTU/hr per square foot.

What does central AC cost to run in Jackson?

About $349 a year: 2,531 kWh at SEER2 14.3 and 13.8¢ per kWh, over 6 cooling months.