What size AC for Huntsville, TX? 4 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Huntsville needs
4 tons central AC or heat pump, about 45,900 BTU/hr of load
Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.8 tons. This is one of the climates the chart was written for.
If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 523 square feet in this climate. For a single room, size by the room: 22.9 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Huntsville Municipal Airport (3.6 mi away). Aug is the hottest month, averaging a high of 95.2°F and a low of 74.4°F, with about 111 days a year at 90°F or more. That gives a design temperature of 103°F against 75°F inside.
What it costs to run
About 4,735 kWh a year at SEER2 14.3, or roughly $759 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 9 months of the year here.
What drives the load in Huntsville
Of the 45,900 BTU/hr, 20,160 comes through walls, roof and windows on a 103°F afternoon (44%), 13,000 is sun on the house (28%), 2,120 is four people and their appliances, and 10,600 is moisture the coil has to wring out of Huntsville's summer air (23%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 35,280 BTU/hr before the moisture allowance.
Other house sizes in Huntsville
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 24,300 | 2 tons | 2 tons |
| 1,500 sq ft | 35,100 | 3 tons | 2.5 tons |
| 2,500 sq ft | 56,600 | 5 tons | 5 tons |
| 3,000 sq ft | 67,400 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,400 BTU/hr; a 350 sq ft living room needs about 8,000 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 13,700 BTU/hr.
Month by month in Huntsville
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 61°F | 12 | 19 |
| Feb | 64.9°F | 22 | 35 |
| Mar | 72.1°F | 64 | 101 |
| Apr | 78.8°F | 146 | 230 |
| May | 86°F | 348 | 547 |
| Jun | 91.7°F | 517 | 813 |
| Jul | 94.2°F | 601 | 945 |
| Aug | 95.2°F | 614 | 964 |
| Sep | 89.7°F | 427 | 671 |
| Oct | 80.7°F | 194 | 305 |
| Nov | 69.9°F | 51 | 80 |
| Dec | 62.3°F | 18 | 28 |
Aug alone uses 20% of the year's cooling energy. The unit runs the equivalent of 1,476 hours a year at full output.
Huntsville against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Conroe, TX | 26 mi | 102°F | 4 tons |
| Tomball, TX | 42 mi | 102°F | 4 tons |
| College Station, TX | 45 mi | 104°F | 4 tons |
| Bryan, TX | 49 mi | 104°F | 4 tons |
| Humble, TX | 52 mi | 103°F | 4 tons |
| Brenham, TX | 63 mi | 103°F | 4 tons |
Of 252 Texas cities here, Huntsville has the 133rd highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.
Where Huntsville's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Huntsville Municipal Airport, 3.6 miles from the center of Huntsville at 346 ft above sea level. That is close enough that the station's summers are Huntsville's summers.
No other city in this set uses Huntsville Municipal Airport, so this sizing is Huntsville's alone.
The sun over Huntsville in late July
At 30.70°N, the noon sun on 21 July stands 79.7° above the horizon over Huntsville and the day runs 13 h 42 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
49,500 people live in Huntsville, the 77th largest of the 252 Texas cities sized on this site. Coordinates used: 30.7005, -95.5549.
Huntsville AC sizing questions
What size AC does a 2,000 sq ft house in Huntsville, TX need?
About 4 tons, for a cooling load of 45,900 BTU/hr on a 103°F design day. That is one ton per 523 square feet in Huntsville's climate.
Is 20 BTU per square foot right for Huntsville?
The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Huntsville Municipal Airport. For a single room here, plan on 22.9 BTU/hr per square foot.
What does central AC cost to run in Huntsville?
About $759 a year: 4,735 kWh at SEER2 14.3 and 16.03¢ per kWh, over 9 cooling months.