What size AC for College Station, TX? 4 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in College Station needs
4 tons central AC or heat pump, about 46,800 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, which falls short here. On a design day the unit runs flat out and the house still drifts above 75°F by late afternoon.
If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 513 square feet in this climate. For a single room, size by the room: 23.4 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at College Station Easterwood Field (4 mi away). Aug is the hottest month, averaging a high of 96.6°F and a low of 74.7°F, with about 117 days a year at 90°F or more. That gives a design temperature of 104°F against 75°F inside.
What it costs to run
About 4,979 kWh a year at SEER2 14.3, or roughly $798 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 9 months of the year here.
What drives the load in College Station
Of the 46,800 BTU/hr, 20,880 comes through walls, roof and windows on a 104°F afternoon (45%), 13,000 is sun on the house (28%), 2,120 is four people and their appliances, and 10,800 is moisture the coil has to wring out of College Station's summer air (23%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,000 BTU/hr before the moisture allowance.
Other house sizes in College Station
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 24,800 | 2 tons | 2 tons |
| 1,500 sq ft | 35,800 | 3 tons | 2.5 tons |
| 2,500 sq ft | 57,800 | 5 tons | 5 tons |
| 3,000 sq ft | 68,800 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,500 BTU/hr; a 350 sq ft living room needs about 8,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 14,000 BTU/hr.
Month by month in College Station
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 61.7°F | 11 | 18 |
| Feb | 65.5°F | 22 | 34 |
| Mar | 72.5°F | 67 | 105 |
| Apr | 79.2°F | 154 | 242 |
| May | 86.3°F | 355 | 557 |
| Jun | 92.2°F | 528 | 829 |
| Jul | 95.4°F | 625 | 981 |
| Aug | 96.6°F | 640 | 1,005 |
| Sep | 91.2°F | 469 | 736 |
| Oct | 81.9°F | 224 | 352 |
| Nov | 71.1°F | 58 | 91 |
| Dec | 63.4°F | 18 | 28 |
Aug alone uses 20% of the year's cooling energy. The unit runs the equivalent of 1,521 hours a year at full output.
College Station against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Bryan, TX | 8 mi | 104°F | 4 tons |
| Brenham, TX | 30 mi | 103°F | 4 tons |
| Huntsville, TX | 45 mi | 103°F | 4 tons |
| Conroe, TX | 51 mi | 102°F | 4 tons |
| Tomball, TX | 53 mi | 102°F | 4 tons |
| Katy, TX | 61 mi | 103°F | 4 tons |
Of 252 Texas cities here, College Station has the 77th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.
Where College Station's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is College Station Easterwood Field, 4 miles from the center of College Station at 315 ft above sea level. That is close enough that the station's summers are College Station's summers.
1 other city uses the same station and get the same climate inputs. The closest to College Station: Bryan (8 mi away, 5.3 mi from the station). College Station sits closer to the station than any of them, so its numbers are the best measured of the group.
The sun over College Station in late July
At 30.59°N, the noon sun on 21 July stands 79.8° above the horizon over College Station and the day runs 13 h 42 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
128,023 people live in College Station, the 31st largest of the 252 Texas cities sized on this site. Coordinates used: 30.5852, -96.2964.
College Station AC sizing questions
What size AC does a 2,000 sq ft house in College Station, TX need?
About 4 tons, for a cooling load of 46,800 BTU/hr on a 104°F design day. That is one ton per 513 square feet in College Station's climate.
Is 20 BTU per square foot right for College Station?
The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at College Station Easterwood Field. For a single room here, plan on 23.4 BTU/hr per square foot.
What does central AC cost to run in College Station?
About $798 a year: 4,979 kWh at SEER2 14.3 and 16.03¢ per kWh, over 9 cooling months.