What size AC for Hendersonville, TN? 3.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Hendersonville needs
3.5 tons central AC or heat pump, about 37,800 BTU/hr of load
Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.1 tons. This is one of the climates the chart was written for.
If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 635 square feet in this climate. For a single room, size by the room: 18.9 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Nashville International Airport (14.4 mi away). Jul is the hottest month, averaging a high of 90.9°F and a low of 70.5°F, with about 54 days a year at 90°F or more. That gives a design temperature of 97°F against 75°F inside.
What it costs to run
About 2,761 kWh a year at SEER2 14.3, or roughly $381 at Tennessee's average residential rate of 13.8¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in Hendersonville
Of the 37,800 BTU/hr, 15,840 comes through walls, roof and windows on a 97°F afternoon (42%), 13,000 is sun on the house (34%), 2,120 is four people and their appliances, and 6,800 is moisture the coil has to wring out of Hendersonville's summer air (18%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 30,960 BTU/hr before the moisture allowance.
Other house sizes in Hendersonville
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 20,200 | 2 tons | 2 tons |
| 1,500 sq ft | 29,000 | 2.5 tons | 2.5 tons |
| 2,500 sq ft | 46,600 | 4 tons | 5 tons |
| 3,000 sq ft | 55,400 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,800 BTU/hr; a 350 sq ft living room needs about 6,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,300 BTU/hr.
Month by month in Hendersonville
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 49.1°F | 0 | 0 |
| Feb | 53.8°F | 1 | 2 |
| Mar | 62.7°F | 11 | 16 |
| Apr | 72.6°F | 52 | 77 |
| May | 80.4°F | 177 | 260 |
| Jun | 87.7°F | 363 | 535 |
| Jul | 90.9°F | 487 | 718 |
| Aug | 90.4°F | 456 | 672 |
| Sep | 84.4°F | 257 | 379 |
| Oct | 73.5°F | 62 | 92 |
| Nov | 61.4°F | 6 | 9 |
| Dec | 52.2°F | 1 | 2 |
Jul alone uses 26% of the year's cooling energy. The unit runs the equivalent of 1,045 hours a year at full output.
Hendersonville against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Goodlettsville, TN | 6 mi | 97°F | 3.5 tons |
| Mount Juliet, TN | 9 mi | 97°F | 3.5 tons |
| Gallatin, TN | 9 mi | 97°F | 3.5 tons |
| White House, TN | 12 mi | 94°F | 3 tons |
| Nashville-Davidson, TN | 14 mi | 97°F | 3.5 tons |
| Lebanon, TN | 16 mi | 96°F | 3.5 tons |
Of 65 Tennessee cities here, Hendersonville has the 11th highest cooling load. The range runs from Crossville at 27,300 BTU/hr to Memphis at 41,200.
Where Hendersonville's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Nashville International Airport, 14.4 miles from the center of Hendersonville at 587 ft above sea level. That is close enough that the station's summers are Hendersonville's summers.
9 other cities use the same station and get the same climate inputs. The closest to Hendersonville: Goodlettsville (6 mi away, 15.4 mi from the station), Mount Juliet (9 mi away, 11.7 mi from the station), Gallatin (9 mi away, 22.4 mi from the station), Nashville-Davidson (14 mi away, 6.9 mi from the station), La Vergne (20 mi away, 9.4 mi from the station). Hendersonville is farther from the station than 6 of them.
The sun over Hendersonville in late July
At 36.31°N, the noon sun on 21 July stands 74.1° above the horizon over Hendersonville and the day runs 14 h 07 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
63,947 people live in Hendersonville, the 10th largest of the 65 Tennessee cities sized on this site. Coordinates used: 36.3065, -86.6018.
Hendersonville AC sizing questions
What size AC does a 2,000 sq ft house in Hendersonville, TN need?
About 3.5 tons, for a cooling load of 37,800 BTU/hr on a 97°F design day. That is one ton per 635 square feet in Hendersonville's climate.
Is 20 BTU per square foot right for Hendersonville?
The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Nashville International Airport. For a single room here, plan on 18.9 BTU/hr per square foot.
What does central AC cost to run in Hendersonville?
About $381 a year: 2,761 kWh at SEER2 14.3 and 13.8¢ per kWh, over 7 cooling months.