What size AC for Flint, MI? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Flint needs

2 tons central AC or heat pump, about 24,900 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 69% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 965 square feet in this climate. For a single room, size by the room: 12.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Flint Fcwos (4.9 mi away). Jul is the hottest month, averaging a high of 82.1°F and a low of 59.7°F, with about 11 days a year at 90°F or more. That gives a design temperature of 86°F against 75°F inside.

What it costs to run

About 737 kWh a year at SEER2 14.3, or roughly $160 at Michigan's average residential rate of 21.73¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Flint

Of the 24,900 BTU/hr, 7,920 comes through walls, roof and windows on a 86°F afternoon (32%), 13,000 is sun on the house (52%), 2,120 is four people and their appliances, and 1,800 is moisture the coil has to wring out of Flint's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,040 BTU/hr before the moisture allowance.

Other house sizes in Flint

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft13,6001.5 tons2 tons
1,500 sq ft19,2001.5 tons2.5 tons
2,500 sq ft30,5002.5 tons5 tons
3,000 sq ft36,2003 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,400 BTU/hr.

Month by month in Flint

MonthAvg highCooling degree daysAC kWh
Jan29.9°F00
Feb32.8°F00
Mar43.3°F11
Apr56.7°F23
May68.9°F3445
Jun78.2°F119156
Jul82.1°F196256
Aug79.9°F152198
Sep73.1°F5572
Oct60.1°F68
Nov46.6°F00
Dec34.9°F00

Jul alone uses 35% of the year's cooling energy. The unit runs the equivalent of 424 hours a year at full output.

Flint against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Burton, MI4 mi86°F2 tons
Fenton, MI16 mi86°F2 tons
Owosso, MI25 mi86°F2 tons
Saginaw, MI30 mi86°F2 tons
Pontiac, MI33 mi87°F2 tons
Auburn Hills, MI33 mi87°F2 tons

Of 90 Michigan cities here, Flint has the 72nd highest cooling load. The range runs from Marquette at 18,700 BTU/hr to Ypsilanti at 28,800.

Where Flint's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Flint Fcwos, 4.9 miles from the center of Flint at 770 ft above sea level. That is close enough that the station's summers are Flint's summers.

2 other cities use the same station and get the same climate inputs. The closest to Flint: Burton (4 mi away, 7.1 mi from the station), Fenton (16 mi away, 11.6 mi from the station). Flint sits closer to the station than any of them, so its numbers are the best measured of the group.

The sun over Flint in late July

At 43.02°N, the noon sun on 21 July stands 67.4° above the horizon over Flint and the day runs 14 h 42 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

79,735 people live in Flint, the 12th largest of the 90 Michigan cities sized on this site. Coordinates used: 43.0244, -83.6920.

Flint AC sizing questions

What size AC does a 2,000 sq ft house in Flint, MI need?

About 2 tons, for a cooling load of 24,900 BTU/hr on a 86°F design day. That is one ton per 965 square feet in Flint's climate.

Is 20 BTU per square foot right for Flint?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Flint Fcwos. For a single room here, plan on 12.4 BTU/hr per square foot.

What does central AC cost to run in Flint?

About $160 a year: 737 kWh at SEER2 14.3 and 21.73¢ per kWh, over 4 cooling months.