What size AC for Auburn Hills, MI? 2 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Auburn Hills needs
2 tons central AC or heat pump, about 25,700 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 64% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 935 square feet in this climate. For a single room, size by the room: 12.8 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Pontiac Oakland County International Airport (8.5 mi away). Jul is the hottest month, averaging a high of 82.2°F and a low of 62.1°F, with about 10 days a year at 90°F or more. That gives a design temperature of 87°F against 75°F inside.
What it costs to run
About 859 kWh a year at SEER2 14.3, or roughly $187 at Michigan's average residential rate of 21.73¢ per kWh. Cooling runs 4 months of the year here.
What drives the load in Auburn Hills
Of the 25,700 BTU/hr, 8,640 comes through walls, roof and windows on a 87°F afternoon (34%), 13,000 is sun on the house (51%), 2,120 is four people and their appliances, and 1,900 is moisture the coil has to wring out of Auburn Hills's summer air (7%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,760 BTU/hr before the moisture allowance.
Other house sizes in Auburn Hills
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 14,000 | 1.5 tons | 2 tons |
| 1,500 sq ft | 19,800 | 1.5 tons | 2.5 tons |
| 2,500 sq ft | 31,500 | 3 tons | 5 tons |
| 3,000 sq ft | 37,300 | 3.5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,700 BTU/hr.
Month by month in Auburn Hills
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 30.4°F | 0 | 0 |
| Feb | 33.2°F | 0 | 0 |
| Mar | 43.2°F | 0 | 1 |
| Apr | 56.7°F | 2 | 3 |
| May | 68.9°F | 35 | 46 |
| Jun | 78.4°F | 136 | 178 |
| Jul | 82.2°F | 229 | 299 |
| Aug | 80°F | 187 | 244 |
| Sep | 72.7°F | 62 | 81 |
| Oct | 60°F | 6 | 8 |
| Nov | 46.2°F | 0 | 0 |
| Dec | 34.9°F | 0 | 0 |
Jul alone uses 35% of the year's cooling energy. The unit runs the equivalent of 479 hours a year at full output.
Auburn Hills against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Pontiac, MI | 3 mi | 87°F | 2 tons |
| Rochester Hills, MI | 4 mi | 87°F | 2 tons |
| Rochester, MI | 6 mi | 87°F | 2 tons |
| Troy, MI | 8 mi | 88°F | 2.5 tons |
| Birmingham, MI | 9 mi | 87°F | 2 tons |
| Beverly Hills, MI | 11 mi | 87°F | 2 tons |
Of 90 Michigan cities here, Auburn Hills has the 57th highest cooling load. The range runs from Marquette at 18,700 BTU/hr to Ypsilanti at 28,800.
Where Auburn Hills's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Pontiac Oakland County International Airport, 8.5 miles from the center of Auburn Hills at 969 ft above sea level. That is close enough that the station's summers are Auburn Hills's summers.
9 other cities use the same station and get the same climate inputs. The closest to Auburn Hills: Pontiac (3 mi away, 6.3 mi from the station), Rochester Hills (4 mi away, 12.8 mi from the station), Rochester (6 mi away, 14.9 mi from the station), Birmingham (9 mi away, 12.8 mi from the station), Beverly Hills (11 mi away, 13 mi from the station). Auburn Hills is farther from the station than 1 of them.
The sun over Auburn Hills in late July
At 42.67°N, the noon sun on 21 July stands 67.7° above the horizon over Auburn Hills and the day runs 14 h 40 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
26,047 people live in Auburn Hills, the 44th largest of the 90 Michigan cities sized on this site. Coordinates used: 42.6747, -83.2436.
Auburn Hills AC sizing questions
What size AC does a 2,000 sq ft house in Auburn Hills, MI need?
About 2 tons, for a cooling load of 25,700 BTU/hr on a 87°F design day. That is one ton per 935 square feet in Auburn Hills's climate.
Is 20 BTU per square foot right for Auburn Hills?
The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Pontiac Oakland County International Airport. For a single room here, plan on 12.8 BTU/hr per square foot.
What does central AC cost to run in Auburn Hills?
About $187 a year: 859 kWh at SEER2 14.3 and 21.73¢ per kWh, over 4 cooling months.