ACSizeCheck

What size AC for Eagle Mountain, UT? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Eagle Mountain needs

3 tons central AC or heat pump, about 31,500 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 34% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 763 square feet in this climate. For a single room, size by the room: 15.7 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Fairfield (5.5 mi away). Jul is the hottest month, averaging a high of 90.2°F and a low of 51°F, with about 43 days a year at 90°F or more. That gives a design temperature of 96°F against 75°F inside.

What it costs to run

About 510 kWh a year at SEER2 14.3, or roughly $67 at Utah's average residential rate of 13.19¢ per kWh. Cooling runs 3 months of the year here.

What drives the load in Eagle Mountain

Of the 31,500 BTU/hr, 15,120 comes through walls, roof and windows on a 96°F afternoon (48%), 13,000 is sun on the house (41%), 2,120 is four people and their appliances, and 1,200 is moisture the coil has to wring out of Eagle Mountain's summer air (4%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 30,240 BTU/hr before the moisture allowance.

Other house sizes in Eagle Mountain

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft16,8001.5 tons2 tons
1,500 sq ft24,1002 tons2.5 tons
2,500 sq ft38,8003.5 tons5 tons
3,000 sq ft46,1004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,400 BTU/hr; a 350 sq ft living room needs about 5,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 9,400 BTU/hr.

Month by month in Eagle Mountain

MonthAvg highCooling degree daysAC kWh
Jan39.3°F00
Feb44.5°F00
Mar56°F00
Apr63°F00
May72.1°F45
Jun82.5°F5467
Jul90.2°F183230
Aug88.6°F140176
Sep80°F2531
Oct66.6°F00
Nov51.8°F00
Dec40.2°F00

Jul alone uses 45% of the year's cooling energy. The unit runs the equivalent of 232 hours a year at full output.

Eagle Mountain against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Saratoga Springs, UT5 mi98°F3 tons
Lehi, UT10 mi98°F3 tons
Bluffdale, UT12 mi100°F3.5 tons
American Fork, UT12 mi99°F3 tons
Herriman, UT12 mi100°F3.5 tons
Vineyard, UT14 mi98°F3 tons

Of 67 Utah cities here, Eagle Mountain has the 63rd highest cooling load. The range runs from Heber at 30,700 BTU/hr to St. George at 49,200.

Where Eagle Mountain's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Fairfield, 5.5 miles from the center of Eagle Mountain at 4,880 ft above sea level. That is close enough that the station's summers are Eagle Mountain's summers.

No other city in this set uses Fairfield, so this sizing is Eagle Mountain's alone.

The sun over Eagle Mountain in late July

At 40.31°N, the noon sun on 21 July stands 70.1° above the horizon over Eagle Mountain and the day runs 14 h 27 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

60,575 people live in Eagle Mountain, the 14th largest of the 67 Utah cities sized on this site. Coordinates used: 40.3143, -112.0120.

Eagle Mountain AC sizing questions

What size AC does a 2,000 sq ft house in Eagle Mountain, UT need?

About 3 tons, for a cooling load of 31,500 BTU/hr on a 96°F design day. That is one ton per 763 square feet in Eagle Mountain's climate.

Is 20 BTU per square foot right for Eagle Mountain?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Fairfield. For a single room here, plan on 15.7 BTU/hr per square foot.

What does central AC cost to run in Eagle Mountain?

About $67 a year: 510 kWh at SEER2 14.3 and 13.19¢ per kWh, over 3 cooling months.