ACSizeCheck

What size AC for American Fork, UT? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in American Fork needs

3 tons central AC or heat pump, about 35,000 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 20% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 686 square feet in this climate. For a single room, size by the room: 17.5 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Pleasant Grove (3.3 mi away). Jul is the hottest month, averaging a high of 93.4°F and a low of 63.9°F, with about 55 days a year at 90°F or more. That gives a design temperature of 99°F against 75°F inside.

What it costs to run

About 1,550 kWh a year at SEER2 14.3, or roughly $204 at Utah's average residential rate of 13.19¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in American Fork

Of the 35,000 BTU/hr, 17,280 comes through walls, roof and windows on a 99°F afternoon (49%), 13,000 is sun on the house (37%), 2,120 is four people and their appliances, and 2,600 is moisture the coil has to wring out of American Fork's summer air (7%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 32,400 BTU/hr before the moisture allowance.

Other house sizes in American Fork

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft18,6001.5 tons2 tons
1,500 sq ft26,8002.5 tons2.5 tons
2,500 sq ft43,2004 tons5 tons
3,000 sq ft51,3004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,600 BTU/hr; a 350 sq ft living room needs about 6,100 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,500 BTU/hr.

Month by month in American Fork

MonthAvg highCooling degree daysAC kWh
Jan40.8°F00
Feb47.2°F00
Mar57.9°F00
Apr64.3°F45
May74.5°F5267
Jun85.1°F200260
Jul93.4°F424553
Aug91.3°F368480
Sep81.8°F132172
Oct67.5°F911
Nov52.9°F00
Dec41.4°F00

Jul alone uses 36% of the year's cooling energy. The unit runs the equivalent of 633 hours a year at full output.

American Fork against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Pleasant Grove, UT3 mi99°F3 tons
Highland, UT3 mi95°F3 tons
Lindon, UT5 mi99°F3 tons
Lehi, UT5 mi98°F3 tons
Vineyard, UT5 mi98°F3 tons
Alpine, UT6 mi95°F3 tons

Of 67 Utah cities here, American Fork has the 44th highest cooling load. The range runs from Heber at 30,700 BTU/hr to St. George at 49,200.

Where American Fork's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Pleasant Grove, 3.3 miles from the center of American Fork at 4,692 ft above sea level. That is close enough that the station's summers are American Fork's summers.

2 other cities use the same station and get the same climate inputs. The closest to American Fork: Pleasant Grove (3 mi away, 0.5 mi from the station), Lindon (5 mi away, 2 mi from the station). American Fork is farther from the station than 2 of them.

The sun over American Fork in late July

At 40.38°N, the noon sun on 21 July stands 70.0° above the horizon over American Fork and the day runs 14 h 27 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

41,298 people live in American Fork, the 23rd largest of the 67 Utah cities sized on this site. Coordinates used: 40.3779, -111.7951.

American Fork AC sizing questions

What size AC does a 2,000 sq ft house in American Fork, UT need?

About 3 tons, for a cooling load of 35,000 BTU/hr on a 99°F design day. That is one ton per 686 square feet in American Fork's climate.

Is 20 BTU per square foot right for American Fork?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Pleasant Grove. For a single room here, plan on 17.5 BTU/hr per square foot.

What does central AC cost to run in American Fork?

About $204 a year: 1,550 kWh at SEER2 14.3 and 13.19¢ per kWh, over 5 cooling months.