ACSizeCheck

What size AC for Duncanville, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Duncanville needs

4 tons central AC or heat pump, about 46,800 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, which falls short here. On a design day the unit runs flat out and the house still drifts above 75°F by late afternoon.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 513 square feet in this climate. For a single room, size by the room: 23.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Dallas Redbird Airport (3.5 mi away). Aug is the hottest month, averaging a high of 96.4°F and a low of 75°F, with about 104 days a year at 90°F or more. That gives a design temperature of 104°F against 75°F inside.

What it costs to run

About 4,453 kWh a year at SEER2 14.3, or roughly $714 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Duncanville

Of the 46,800 BTU/hr, 20,880 comes through walls, roof and windows on a 104°F afternoon (45%), 13,000 is sun on the house (28%), 2,120 is four people and their appliances, and 10,800 is moisture the coil has to wring out of Duncanville's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,000 BTU/hr before the moisture allowance.

Other house sizes in Duncanville

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft24,8002 tons2 tons
1,500 sq ft35,8003 tons2.5 tons
2,500 sq ft57,8005 tons5 tons
3,000 sq ft68,8005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,500 BTU/hr; a 350 sq ft living room needs about 8,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 14,000 BTU/hr.

Month by month in Duncanville

MonthAvg highCooling degree daysAC kWh
Jan57.4°F45
Feb61.5°F1016
Mar69°F3860
Apr76.2°F100157
May83.6°F285448
Jun91.4°F501787
Jul95.9°F6401,006
Aug96.4°F6421,008
Sep89.3°F415651
Oct78.8°F164258
Nov67.3°F3047
Dec58.8°F69

Aug alone uses 23% of the year's cooling energy. The unit runs the equivalent of 1,361 hours a year at full output.

Duncanville against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
DeSoto, TX4 mi104°F4 tons
Cedar Hill, TX5 mi104°F4 tons
Grand Prairie, TX7 mi104°F4 tons
Glenn Heights, TX7 mi104°F4 tons
Lancaster, TX9 mi104°F4 tons
Red Oak, TX12 mi104°F4 tons

Of 252 Texas cities here, Duncanville has the 88th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Duncanville's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Dallas Redbird Airport, 3.5 miles from the center of Duncanville at 658 ft above sea level. That is close enough that the station's summers are Duncanville's summers.

6 other cities use the same station and get the same climate inputs. The closest to Duncanville: DeSoto (4 mi away, 5.4 mi from the station), Cedar Hill (5 mi away, 8.4 mi from the station), Glenn Heights (7 mi away, 8.8 mi from the station), Lancaster (9 mi away, 7.9 mi from the station), Red Oak (12 mi away, 12.6 mi from the station). Duncanville sits closer to the station than any of them, so its numbers are the best measured of the group.

The sun over Duncanville in late July

At 32.65°N, the noon sun on 21 July stands 77.8° above the horizon over Duncanville and the day runs 13 h 50 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

39,203 people live in Duncanville, the 95th largest of the 252 Texas cities sized on this site. Coordinates used: 32.6459, -96.9139.

Duncanville AC sizing questions

What size AC does a 2,000 sq ft house in Duncanville, TX need?

About 4 tons, for a cooling load of 46,800 BTU/hr on a 104°F design day. That is one ton per 513 square feet in Duncanville's climate.

Is 20 BTU per square foot right for Duncanville?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Dallas Redbird Airport. For a single room here, plan on 23.4 BTU/hr per square foot.

What does central AC cost to run in Duncanville?

About $714 a year: 4,453 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.