What size AC for Cedar Hill, TX? 4 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Cedar Hill needs
4 tons central AC or heat pump, about 46,800 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, which falls short here. On a design day the unit runs flat out and the house still drifts above 75°F by late afternoon.
If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 513 square feet in this climate. For a single room, size by the room: 23.4 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Dallas Redbird Airport (8.4 mi away). Aug is the hottest month, averaging a high of 96.4°F and a low of 75°F, with about 104 days a year at 90°F or more. That gives a design temperature of 104°F against 75°F inside.
What it costs to run
About 4,453 kWh a year at SEER2 14.3, or roughly $714 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in Cedar Hill
Of the 46,800 BTU/hr, 20,880 comes through walls, roof and windows on a 104°F afternoon (45%), 13,000 is sun on the house (28%), 2,120 is four people and their appliances, and 10,800 is moisture the coil has to wring out of Cedar Hill's summer air (23%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,000 BTU/hr before the moisture allowance.
Other house sizes in Cedar Hill
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 24,800 | 2 tons | 2 tons |
| 1,500 sq ft | 35,800 | 3 tons | 2.5 tons |
| 2,500 sq ft | 57,800 | 5 tons | 5 tons |
| 3,000 sq ft | 68,800 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,500 BTU/hr; a 350 sq ft living room needs about 8,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 14,000 BTU/hr.
Month by month in Cedar Hill
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 57.4°F | 4 | 5 |
| Feb | 61.5°F | 10 | 16 |
| Mar | 69°F | 38 | 60 |
| Apr | 76.2°F | 100 | 157 |
| May | 83.6°F | 285 | 448 |
| Jun | 91.4°F | 501 | 787 |
| Jul | 95.9°F | 640 | 1,006 |
| Aug | 96.4°F | 642 | 1,008 |
| Sep | 89.3°F | 415 | 651 |
| Oct | 78.8°F | 164 | 258 |
| Nov | 67.3°F | 30 | 47 |
| Dec | 58.8°F | 6 | 9 |
Aug alone uses 23% of the year's cooling energy. The unit runs the equivalent of 1,361 hours a year at full output.
Cedar Hill against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Duncanville, TX | 5 mi | 104°F | 4 tons |
| DeSoto, TX | 6 mi | 104°F | 4 tons |
| Glenn Heights, TX | 6 mi | 104°F | 4 tons |
| Grand Prairie, TX | 7 mi | 104°F | 4 tons |
| Midlothian, TX | 8 mi | 104°F | 4 tons |
| Mansfield, TX | 9 mi | 104°F | 4 tons |
Of 252 Texas cities here, Cedar Hill has the 83rd highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.
Where Cedar Hill's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Dallas Redbird Airport, 8.4 miles from the center of Cedar Hill at 658 ft above sea level. That is close enough that the station's summers are Cedar Hill's summers.
6 other cities use the same station and get the same climate inputs. The closest to Cedar Hill: Duncanville (5 mi away, 3.5 mi from the station), DeSoto (6 mi away, 5.4 mi from the station), Glenn Heights (6 mi away, 8.8 mi from the station), Lancaster (11 mi away, 7.9 mi from the station), Red Oak (11 mi away, 12.6 mi from the station). Cedar Hill is farther from the station than 3 of them.
The sun over Cedar Hill in late July
At 32.58°N, the noon sun on 21 July stands 77.8° above the horizon over Cedar Hill and the day runs 13 h 50 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
49,618 people live in Cedar Hill, the 76th largest of the 252 Texas cities sized on this site. Coordinates used: 32.5843, -96.9589.
Cedar Hill AC sizing questions
What size AC does a 2,000 sq ft house in Cedar Hill, TX need?
About 4 tons, for a cooling load of 46,800 BTU/hr on a 104°F design day. That is one ton per 513 square feet in Cedar Hill's climate.
Is 20 BTU per square foot right for Cedar Hill?
The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Dallas Redbird Airport. For a single room here, plan on 23.4 BTU/hr per square foot.
What does central AC cost to run in Cedar Hill?
About $714 a year: 4,453 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.