What size AC for Davie, FL? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Davie needs

4 tons central AC or heat pump, about 42,100 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.5 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 570 square feet in this climate. For a single room, size by the room: 21.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Hollywood N Perry Airport (6.1 mi away). Aug is the hottest month, averaging a high of 91.8°F and a low of 77.5°F, with about 105 days a year at 90°F or more. That gives a design temperature of 99°F against 75°F inside.

What it costs to run

About 7,288 kWh a year at SEER2 14.3, or roughly $1,117 at Florida's average residential rate of 15.32¢ per kWh. Cooling runs 12 months of the year here.

What drives the load in Davie

Of the 42,100 BTU/hr, 17,280 comes through walls, roof and windows on a 99°F afternoon (41%), 13,000 is sun on the house (31%), 2,120 is four people and their appliances, and 9,700 is moisture the coil has to wring out of Davie's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 32,400 BTU/hr before the moisture allowance.

Other house sizes in Davie

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft22,4002 tons2 tons
1,500 sq ft32,3003 tons2.5 tons
2,500 sq ft52,0004 tons5 tons
3,000 sq ft61,8005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,200 BTU/hr; a 350 sq ft living room needs about 7,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,700 BTU/hr.

Month by month in Davie

MonthAvg highCooling degree daysAC kWh
Jan76.9°F148233
Feb78.9°F171268
Mar81.3°F249390
Apr84.5°F343539
May87.3°F465730
Jun90°F538846
Jul91.7°F601945
Aug91.8°F609957
Sep89.8°F545855
Oct86.8°F468736
Nov82.2°F294462
Dec78.6°F208327

Aug alone uses 13% of the year's cooling energy. The unit runs the equivalent of 2,474 hours a year at full output.

Davie against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Cooper City, FL2 mi99°F4 tons
Plantation, FL3 mi96°F3.5 tons
Pembroke Pines, FL6 mi99°F4 tons
Sunrise, FL7 mi99°F4 tons
Lauderhill, FL7 mi99°F4 tons
Dania Beach, FL8 mi96°F3.5 tons

Of 173 Florida cities here, Davie has the 42nd highest cooling load. The range runs from Miami Shores at 36,500 BTU/hr to Plant City at 44,900.

Where Davie's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Hollywood N Perry Airport, 6.1 miles from the center of Davie at 6 ft above sea level. That is close enough that the station's summers are Davie's summers.

9 other cities use the same station and get the same climate inputs. The closest to Davie: Cooper City (2 mi away, 4.3 mi from the station), Pembroke Pines (6 mi away, 6.2 mi from the station), Weston (8 mi away, 12.2 mi from the station), Miami Gardens (9 mi away, 3.5 mi from the station), West Park (9 mi away, 4 mi from the station). Davie is farther from the station than 3 of them.

The sun over Davie in late July

At 26.08°N, the noon sun on 21 July stands 84.3° above the horizon over Davie and the day runs 13 h 24 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.

112,052 people live in Davie, the 22nd largest of the 173 Florida cities sized on this site. Coordinates used: 26.0792, -80.2830.

Davie AC sizing questions

What size AC does a 2,000 sq ft house in Davie, FL need?

About 4 tons, for a cooling load of 42,100 BTU/hr on a 99°F design day. That is one ton per 570 square feet in Davie's climate.

Is 20 BTU per square foot right for Davie?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Hollywood N Perry Airport. For a single room here, plan on 21.1 BTU/hr per square foot.

What does central AC cost to run in Davie?

About $1,117 a year: 7,288 kWh at SEER2 14.3 and 15.32¢ per kWh, over 12 cooling months.