ACSizeCheck

What size AC for Lauderhill, FL? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Lauderhill needs

4 tons central AC or heat pump, about 42,100 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.5 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 570 square feet in this climate. For a single room, size by the room: 21.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Fort Lauderdale Executive Airport (3.9 mi away). Aug is the hottest month, averaging a high of 91.4°F and a low of 76.8°F, with about 93 days a year at 90°F or more. That gives a design temperature of 99°F against 75°F inside.

What it costs to run

About 7,031 kWh a year at SEER2 14.3, or roughly $1,077 at Florida's average residential rate of 15.32¢ per kWh. Cooling runs 12 months of the year here.

What drives the load in Lauderhill

Of the 42,100 BTU/hr, 17,280 comes through walls, roof and windows on a 99°F afternoon (41%), 13,000 is sun on the house (31%), 2,120 is four people and their appliances, and 9,700 is moisture the coil has to wring out of Lauderhill's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 32,400 BTU/hr before the moisture allowance.

Other house sizes in Lauderhill

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft22,4002 tons2 tons
1,500 sq ft32,3003 tons2.5 tons
2,500 sq ft52,0004 tons5 tons
3,000 sq ft61,8005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,200 BTU/hr; a 350 sq ft living room needs about 7,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,700 BTU/hr.

Month by month in Lauderhill

MonthAvg highCooling degree daysAC kWh
Jan76.2°F140221
Feb78°F160251
Mar80.7°F238374
Apr83.9°F335526
May86.9°F453711
Jun89.2°F520818
Jul91.1°F581913
Aug91.4°F592930
Sep89.4°F530832
Oct86.3°F456716
Nov81°F273429
Dec77.8°F199312

Aug alone uses 13% of the year's cooling energy. The unit runs the equivalent of 2,387 hours a year at full output.

Lauderhill against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Lauderdale Lakes, FL2 mi99°F4 tons
Sunrise, FL2 mi99°F4 tons
Plantation, FL3 mi96°F3.5 tons
Tamarac, FL3 mi99°F4 tons
North Lauderdale, FL4 mi99°F4 tons
Oakland Park, FL5 mi99°F4 tons

Of 173 Florida cities here, Lauderhill has the 45th highest cooling load. The range runs from Miami Shores at 36,500 BTU/hr to Plant City at 44,900.

Where Lauderhill's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Fort Lauderdale Executive Airport, 3.9 miles from the center of Lauderhill at 12 ft above sea level. That is close enough that the station's summers are Lauderhill's summers.

9 other cities use the same station and get the same climate inputs. The closest to Lauderhill: Lauderdale Lakes (2 mi away, 2.6 mi from the station), Sunrise (2 mi away, 5.5 mi from the station), Tamarac (3 mi away, 4.9 mi from the station), North Lauderdale (4 mi away, 2.9 mi from the station), Oakland Park (5 mi away, 2.1 mi from the station). Lauderhill is farther from the station than 4 of them.

The sun over Lauderhill in late July

At 26.16°N, the noon sun on 21 July stands 84.2° above the horizon over Lauderhill and the day runs 13 h 24 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.

76,627 people live in Lauderhill, the 39th largest of the 173 Florida cities sized on this site. Coordinates used: 26.1616, -80.2251.

Lauderhill AC sizing questions

What size AC does a 2,000 sq ft house in Lauderhill, FL need?

About 4 tons, for a cooling load of 42,100 BTU/hr on a 99°F design day. That is one ton per 570 square feet in Lauderhill's climate.

Is 20 BTU per square foot right for Lauderhill?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Fort Lauderdale Executive Airport. For a single room here, plan on 21.1 BTU/hr per square foot.

What does central AC cost to run in Lauderhill?

About $1,077 a year: 7,031 kWh at SEER2 14.3 and 15.32¢ per kWh, over 12 cooling months.