What size AC for Cullman, AL? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Cullman needs

3 tons central AC or heat pump, about 32,300 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 30% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 743 square feet in this climate. For a single room, size by the room: 16.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Cullman 3 Ene (2.8 mi away). Jul is the hottest month, averaging a high of 87.9°F and a low of 67.5°F, with about 39 days a year at 90°F or more. That gives a design temperature of 93°F against 75°F inside.

What it costs to run

About 2,044 kWh a year at SEER2 14.3, or roughly $337 at Alabama's average residential rate of 16.51¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Cullman

Of the 32,300 BTU/hr, 12,960 comes through walls, roof and windows on a 93°F afternoon (40%), 13,000 is sun on the house (40%), 2,120 is four people and their appliances, and 4,200 is moisture the coil has to wring out of Cullman's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 28,080 BTU/hr before the moisture allowance.

Other house sizes in Cullman

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft17,4001.5 tons2 tons
1,500 sq ft24,8002 tons2.5 tons
2,500 sq ft39,8003.5 tons5 tons
3,000 sq ft47,2004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,400 BTU/hr; a 350 sq ft living room needs about 5,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 9,700 BTU/hr.

Month by month in Cullman

MonthAvg highCooling degree daysAC kWh
Jan51.1°F00
Feb55.3°F11
Mar63.2°F45
Apr71.6°F2635
May78.8°F119166
Jun85.8°F293407
Jul87.9°F394547
Aug87.7°F380528
Sep82.6°F207287
Oct73.5°F4563
Nov61.8°F35
Dec53.8°F00

Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 905 hours a year at full output.

Cullman against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Hartselle, AL19 mi96°F3.5 tons
Decatur, AL29 mi96°F3.5 tons
Jasper, AL33 mi96°F3.5 tons
Gardendale, AL35 mi97°F3.5 tons
Clay, AL36 mi97°F3.5 tons
Albertville, AL36 mi91°F2.5 tons

Of 66 Alabama cities here, Cullman has the 62nd highest cooling load. The range runs from Boaz at 30,600 BTU/hr to Montgomery at 44,000.

Where Cullman's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Cullman 3 Ene, 2.8 miles from the center of Cullman at 800 ft above sea level. That is close enough that the station's summers are Cullman's summers.

No other city in this set uses Cullman 3 Ene, so this sizing is Cullman's alone.

The sun over Cullman in late July

At 34.18°N, the noon sun on 21 July stands 76.2° above the horizon over Cullman and the day runs 13 h 57 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

20,239 people live in Cullman, the 33rd largest of the 66 Alabama cities sized on this site. Coordinates used: 34.1769, -86.8407.

Cullman AC sizing questions

What size AC does a 2,000 sq ft house in Cullman, AL need?

About 3 tons, for a cooling load of 32,300 BTU/hr on a 93°F design day. That is one ton per 743 square feet in Cullman's climate.

Is 20 BTU per square foot right for Cullman?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Cullman 3 Ene. For a single room here, plan on 16.1 BTU/hr per square foot.

What does central AC cost to run in Cullman?

About $337 a year: 2,044 kWh at SEER2 14.3 and 16.51¢ per kWh, over 5 cooling months.