What size AC for Albertville, AL? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Albertville needs
2.5 tons central AC or heat pump, about 30,600 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 37% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 783 square feet in this climate. For a single room, size by the room: 15.3 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Gadsden 19 N (14.3 mi away). Jul is the hottest month, averaging a high of 86.5°F and a low of 66.7°F, with about 26 days a year at 90°F or more. That gives a design temperature of 91°F against 75°F inside.
What it costs to run
About 1,793 kWh a year at SEER2 14.3, or roughly $296 at Alabama's average residential rate of 16.51¢ per kWh. Cooling runs 5 months of the year here.
What drives the load in Albertville
Of the 30,600 BTU/hr, 11,520 comes through walls, roof and windows on a 91°F afternoon (38%), 13,000 is sun on the house (42%), 2,120 is four people and their appliances, and 4,000 is moisture the coil has to wring out of Albertville's summer air (13%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 26,640 BTU/hr before the moisture allowance.
Other house sizes in Albertville
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 16,500 | 1.5 tons | 2 tons |
| 1,500 sq ft | 23,600 | 2 tons | 2.5 tons |
| 2,500 sq ft | 37,700 | 3.5 tons | 5 tons |
| 3,000 sq ft | 44,700 | 4 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,300 BTU/hr; a 350 sq ft living room needs about 5,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 9,200 BTU/hr.
Month by month in Albertville
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 49.5°F | 0 | 0 |
| Feb | 53.9°F | 0 | 0 |
| Mar | 61.4°F | 3 | 4 |
| Apr | 69.7°F | 22 | 30 |
| May | 77°F | 99 | 137 |
| Jun | 83.7°F | 248 | 344 |
| Jul | 86.5°F | 360 | 500 |
| Aug | 86°F | 337 | 468 |
| Sep | 81.4°F | 184 | 255 |
| Oct | 71.4°F | 36 | 50 |
| Nov | 60.6°F | 2 | 3 |
| Dec | 52.2°F | 0 | 1 |
Jul alone uses 28% of the year's cooling energy. The unit runs the equivalent of 837 hours a year at full output.
Albertville against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Boaz, AL | 5 mi | 91°F | 2.5 tons |
| Gadsden, AL | 21 mi | 97°F | 3.5 tons |
| Rainbow City, AL | 24 mi | 97°F | 3.5 tons |
| Scottsboro, AL | 28 mi | 94°F | 3 tons |
| Fort Payne, AL | 33 mi | 92°F | 3 tons |
| Cullman, AL | 36 mi | 93°F | 3 tons |
Of 66 Alabama cities here, Albertville has the 65th highest cooling load. The range runs from Boaz at 30,600 BTU/hr to Montgomery at 44,000.
Where Albertville's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Gadsden 19 N, 14.3 miles from the center of Albertville at 1,152 ft above sea level. That is close enough that the station's summers are Albertville's summers.
1 other city uses the same station and get the same climate inputs. The closest to Albertville: Boaz (5 mi away, 12.5 mi from the station). Albertville is farther from the station than 1 of them.
The sun over Albertville in late July
At 34.26°N, the noon sun on 21 July stands 76.1° above the horizon over Albertville and the day runs 13 h 57 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
23,392 people live in Albertville, the 28th largest of the 66 Alabama cities sized on this site. Coordinates used: 34.2631, -86.2107.
Albertville AC sizing questions
What size AC does a 2,000 sq ft house in Albertville, AL need?
About 2.5 tons, for a cooling load of 30,600 BTU/hr on a 91°F design day. That is one ton per 783 square feet in Albertville's climate.
Is 20 BTU per square foot right for Albertville?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Gadsden 19 N. For a single room here, plan on 15.3 BTU/hr per square foot.
What does central AC cost to run in Albertville?
About $296 a year: 1,793 kWh at SEER2 14.3 and 16.51¢ per kWh, over 5 cooling months.