ACSizeCheck

What size AC for Cottage Grove, OR? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Cottage Grove needs

2 tons central AC or heat pump, about 24,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 70% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 971 square feet in this climate. For a single room, size by the room: 12.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Cottage Grove 2e (1.5 mi away). Aug is the hottest month, averaging a high of 82.6°F and a low of 50.4°F, with about 16 days a year at 90°F or more. That gives a design temperature of 87°F against 75°F inside.

What it costs to run

About 282 kWh a year at SEER2 14.3, or roughly $44 at Oregon's average residential rate of 15.46¢ per kWh. Cooling runs 2 months of the year here.

What drives the load in Cottage Grove

Of the 24,700 BTU/hr, 8,640 comes through walls, roof and windows on a 87°F afternoon (35%), 13,000 is sun on the house (53%), 2,120 is four people and their appliances, and 1,000 is moisture the coil has to wring out of Cottage Grove's summer air (4%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,760 BTU/hr before the moisture allowance.

Other house sizes in Cottage Grove

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft13,5001.5 tons2 tons
1,500 sq ft19,1001.5 tons2.5 tons
2,500 sq ft30,3002.5 tons5 tons
3,000 sq ft36,0003 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,400 BTU/hr.

Month by month in Cottage Grove

MonthAvg highCooling degree daysAC kWh
Jan48.1°F00
Feb51.7°F00
Mar56.3°F00
Apr61.1°F00
May67.8°F57
Jun73.2°F2227
Jul82°F88111
Aug82.6°F85106
Sep76.5°F2430
Oct64.1°F01
Nov53°F00
Dec46.7°F00

Jul alone uses 39% of the year's cooling energy. The unit runs the equivalent of 163 hours a year at full output.

Cottage Grove against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Springfield, OR18 mi89°F2.5 tons
Eugene, OR18 mi89°F2.5 tons
Roseburg, OR42 mi91°F2.5 tons
Sweet Home, OR46 mi87°F2 tons
Lebanon, OR51 mi91°F2.5 tons
Corvallis, OR55 mi87°F2 tons

Of 57 Oregon cities here, Cottage Grove has the 50th highest cooling load. The range runs from North Bend at 15,700 BTU/hr to Ontario at 36,500.

Where Cottage Grove's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Cottage Grove 2e, 1.5 miles from the center of Cottage Grove at 595 ft above sea level. That is close enough that the station's summers are Cottage Grove's summers.

No other city in this set uses Cottage Grove 2e, so this sizing is Cottage Grove's alone.

The sun over Cottage Grove in late July

At 43.80°N, the noon sun on 21 July stands 66.6° above the horizon over Cottage Grove and the day runs 14 h 47 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

10,690 people live in Cottage Grove, the 50th largest of the 57 Oregon cities sized on this site. Coordinates used: 43.7959, -123.0572.

Cottage Grove AC sizing questions

What size AC does a 2,000 sq ft house in Cottage Grove, OR need?

About 2 tons, for a cooling load of 24,700 BTU/hr on a 87°F design day. That is one ton per 971 square feet in Cottage Grove's climate.

Is 20 BTU per square foot right for Cottage Grove?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Cottage Grove 2e. For a single room here, plan on 12.4 BTU/hr per square foot.

What does central AC cost to run in Cottage Grove?

About $44 a year: 282 kWh at SEER2 14.3 and 15.46¢ per kWh, over 2 cooling months.