ACSizeCheck

What size AC for Corvallis, OR? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Corvallis needs

2 tons central AC or heat pump, about 24,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 70% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 971 square feet in this climate. For a single room, size by the room: 12.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Corvallis 10 Ssw (10.7 mi away). Aug is the hottest month, averaging a high of 82.1°F and a low of 50.7°F, with about 15 days a year at 90°F or more. That gives a design temperature of 87°F against 75°F inside.

What it costs to run

About 271 kWh a year at SEER2 14.3, or roughly $42 at Oregon's average residential rate of 15.46¢ per kWh. Cooling runs 2 months of the year here.

What drives the load in Corvallis

Of the 24,700 BTU/hr, 8,640 comes through walls, roof and windows on a 87°F afternoon (35%), 13,000 is sun on the house (53%), 2,120 is four people and their appliances, and 1,000 is moisture the coil has to wring out of Corvallis's summer air (4%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,760 BTU/hr before the moisture allowance.

Other house sizes in Corvallis

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft13,5001.5 tons2 tons
1,500 sq ft19,1001.5 tons2.5 tons
2,500 sq ft30,3002.5 tons5 tons
3,000 sq ft36,0003 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,400 BTU/hr.

Month by month in Corvallis

MonthAvg highCooling degree daysAC kWh
Jan47.2°F00
Feb50.5°F00
Mar55.4°F00
Apr59.7°F00
May66.7°F34
Jun73.2°F2126
Jul81.8°F81101
Aug82.1°F81101
Sep76.7°F3037
Oct64.3°F11
Nov52.1°F00
Dec45.7°F00

Jul alone uses 37% of the year's cooling energy. The unit runs the equivalent of 157 hours a year at full output.

Corvallis against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Albany, OR10 mi87°F2 tons
Lebanon, OR18 mi91°F2.5 tons
Monmouth, OR20 mi88°F2 tons
Independence, OR20 mi88°F2 tons
Dallas, OR24 mi88°F2 tons
Salem, OR27 mi88°F2 tons

Of 57 Oregon cities here, Corvallis has the 41st highest cooling load. The range runs from North Bend at 15,700 BTU/hr to Ontario at 36,500.

Where Corvallis's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Corvallis 10 Ssw, 10.7 miles from the center of Corvallis at 312 ft above sea level. That is close enough that the station's summers are Corvallis's summers.

1 other city uses the same station and get the same climate inputs. The closest to Corvallis: Albany (10 mi away, 18.3 mi from the station). Corvallis sits closer to the station than any of them, so its numbers are the best measured of the group.

The sun over Corvallis in late July

At 44.57°N, the noon sun on 21 July stands 65.8° above the horizon over Corvallis and the day runs 14 h 52 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

61,993 people live in Corvallis, the 9th largest of the 57 Oregon cities sized on this site. Coordinates used: 44.5699, -123.2783.

Corvallis AC sizing questions

What size AC does a 2,000 sq ft house in Corvallis, OR need?

About 2 tons, for a cooling load of 24,700 BTU/hr on a 87°F design day. That is one ton per 971 square feet in Corvallis's climate.

Is 20 BTU per square foot right for Corvallis?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Corvallis 10 Ssw. For a single room here, plan on 12.4 BTU/hr per square foot.

What does central AC cost to run in Corvallis?

About $42 a year: 271 kWh at SEER2 14.3 and 15.46¢ per kWh, over 2 cooling months.