ACSizeCheck

What size AC for Corsicana, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Corsicana needs

4 tons central AC or heat pump, about 46,800 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, which falls short here. On a design day the unit runs flat out and the house still drifts above 75°F by late afternoon.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 513 square feet in this climate. For a single room, size by the room: 23.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Corsicana Campbell Field (5.3 mi away). Aug is the hottest month, averaging a high of 96°F and a low of 73.7°F, with about 107 days a year at 90°F or more. That gives a design temperature of 104°F against 75°F inside.

What it costs to run

About 4,354 kWh a year at SEER2 14.3, or roughly $698 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Corsicana

Of the 46,800 BTU/hr, 20,880 comes through walls, roof and windows on a 104°F afternoon (45%), 13,000 is sun on the house (28%), 2,120 is four people and their appliances, and 10,800 is moisture the coil has to wring out of Corsicana's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,000 BTU/hr before the moisture allowance.

Other house sizes in Corsicana

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft24,8002 tons2 tons
1,500 sq ft35,8003 tons2.5 tons
2,500 sq ft57,8005 tons5 tons
3,000 sq ft68,8005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,500 BTU/hr; a 350 sq ft living room needs about 8,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 14,000 BTU/hr.

Month by month in Corsicana

MonthAvg highCooling degree daysAC kWh
Jan58.5°F47
Feb62.5°F1219
Mar69.8°F3960
Apr77°F107167
May84.1°F289454
Jun91.2°F486763
Jul95.1°F606952
Aug96°F615966
Sep89.6°F408641
Oct79.8°F167262
Nov67.8°F3047
Dec59.9°F914

Aug alone uses 22% of the year's cooling energy. The unit runs the equivalent of 1,330 hours a year at full output.

Corsicana against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Ennis, TX19 mi103°F4 tons
Waxahachie, TX31 mi103°F4 tons
Red Oak, TX35 mi104°F4 tons
Athens, TX38 mi102°F4 tons
Glenn Heights, TX40 mi104°F4 tons
Seagoville, TX40 mi104°F4 tons

Of 252 Texas cities here, Corsicana has the 96th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Corsicana's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Corsicana Campbell Field, 5.3 miles from the center of Corsicana at 443 ft above sea level. That is close enough that the station's summers are Corsicana's summers.

No other city in this set uses Corsicana Campbell Field, so this sizing is Corsicana's alone.

The sun over Corsicana in late July

At 32.08°N, the noon sun on 21 July stands 78.3° above the horizon over Corsicana and the day runs 13 h 48 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

25,591 people live in Corsicana, the 128th largest of the 252 Texas cities sized on this site. Coordinates used: 32.0824, -96.4667.

Corsicana AC sizing questions

What size AC does a 2,000 sq ft house in Corsicana, TX need?

About 4 tons, for a cooling load of 46,800 BTU/hr on a 104°F design day. That is one ton per 513 square feet in Corsicana's climate.

Is 20 BTU per square foot right for Corsicana?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Corsicana Campbell Field. For a single room here, plan on 23.4 BTU/hr per square foot.

What does central AC cost to run in Corsicana?

About $698 a year: 4,354 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.