ACSizeCheck

What size AC for Waxahachie, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Waxahachie needs

4 tons central AC or heat pump, about 45,900 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.8 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 523 square feet in this climate. For a single room, size by the room: 22.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Waxahachie (1.8 mi away). Aug is the hottest month, averaging a high of 95.3°F and a low of 73.7°F, with about 96 days a year at 90°F or more. That gives a design temperature of 103°F against 75°F inside.

What it costs to run

About 3,994 kWh a year at SEER2 14.3, or roughly $640 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Waxahachie

Of the 45,900 BTU/hr, 20,160 comes through walls, roof and windows on a 103°F afternoon (44%), 13,000 is sun on the house (28%), 2,120 is four people and their appliances, and 10,600 is moisture the coil has to wring out of Waxahachie's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 35,280 BTU/hr before the moisture allowance.

Other house sizes in Waxahachie

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft24,3002 tons2 tons
1,500 sq ft35,1003 tons2.5 tons
2,500 sq ft56,6005 tons5 tons
3,000 sq ft67,4005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,400 BTU/hr; a 350 sq ft living room needs about 8,000 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 13,700 BTU/hr.

Month by month in Waxahachie

MonthAvg highCooling degree daysAC kWh
Jan56.5°F11
Feb60°F35
Mar67.4°F1727
Apr75.3°F74116
May82.3°F248390
Jun90.4°F468735
Jul94.7°F598940
Aug95.3°F604949
Sep88.4°F382600
Oct78.3°F126198
Nov66.3°F1828
Dec57.7°F34

Aug alone uses 24% of the year's cooling energy. The unit runs the equivalent of 1,245 hours a year at full output.

Waxahachie against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Red Oak, TX8 mi104°F4 tons
Midlothian, TX10 mi104°F4 tons
Glenn Heights, TX10 mi104°F4 tons
Ennis, TX13 mi103°F4 tons
DeSoto, TX14 mi104°F4 tons
Lancaster, TX14 mi104°F4 tons

Of 252 Texas cities here, Waxahachie has the 135th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Waxahachie's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Waxahachie, 1.8 miles from the center of Waxahachie at 626 ft above sea level. That is close enough that the station's summers are Waxahachie's summers.

No other city in this set uses Waxahachie, so this sizing is Waxahachie's alone.

The sun over Waxahachie in late July

At 32.40°N, the noon sun on 21 July stands 78.0° above the horizon over Waxahachie and the day runs 13 h 49 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

48,617 people live in Waxahachie, the 79th largest of the 252 Texas cities sized on this site. Coordinates used: 32.4025, -96.8445.

Waxahachie AC sizing questions

What size AC does a 2,000 sq ft house in Waxahachie, TX need?

About 4 tons, for a cooling load of 45,900 BTU/hr on a 103°F design day. That is one ton per 523 square feet in Waxahachie's climate.

Is 20 BTU per square foot right for Waxahachie?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Waxahachie. For a single room here, plan on 22.9 BTU/hr per square foot.

What does central AC cost to run in Waxahachie?

About $640 a year: 3,994 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.