ACSizeCheck

What size AC for Cheyenne, WY? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Cheyenne needs

2.5 tons central AC or heat pump, about 26,200 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 60% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 916 square feet in this climate. For a single room, size by the room: 13.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Cheyenne (1.7 mi away). Jul is the hottest month, averaging a high of 84.1°F and a low of 56.1°F, with about 15 days a year at 90°F or more. That gives a design temperature of 89°F against 75°F inside.

What it costs to run

About 501 kWh a year at SEER2 14.3, or roughly $70 at Wyoming's average residential rate of 14.01¢ per kWh. Cooling runs 3 months of the year here.

What drives the load in Cheyenne

Of the 26,200 BTU/hr, 10,080 comes through walls, roof and windows on a 89°F afternoon (38%), 13,000 is sun on the house (50%), 2,120 is four people and their appliances, and 1,000 is moisture the coil has to wring out of Cheyenne's summer air (4%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,200 BTU/hr before the moisture allowance.

Other house sizes in Cheyenne

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,2001.5 tons2 tons
1,500 sq ft20,2002 tons2.5 tons
2,500 sq ft32,2003 tons5 tons
3,000 sq ft38,2003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,900 BTU/hr.

Month by month in Cheyenne

MonthAvg highCooling degree daysAC kWh
Jan40°F00
Feb40.6°F00
Mar49.1°F00
Apr54.8°F00
May64.4°F45
Jun76.7°F5671
Jul84.1°F175220
Aug82°F130164
Sep73.3°F3241
Oct59.1°F11
Nov47.5°F00
Dec39.3°F00

Jul alone uses 44% of the year's cooling energy. The unit runs the equivalent of 273 hours a year at full output.

Cheyenne against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Wellington, CO32 mi92°F2.5 tons
Timnath, CO42 mi93°F2.5 tons
Fort Collins, CO42 mi92°F2.5 tons
Severance, CO43 mi92°F2.5 tons
Laramie, WY44 mi85°F2 tons
Windsor, CO45 mi93°F2.5 tons

Of 11 Wyoming cities here, Cheyenne has the 6th highest cooling load. The range runs from Jackson at 21,700 BTU/hr to Casper at 30,000.

Where Cheyenne's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Cheyenne, 1.7 miles from the center of Cheyenne at 6,193 ft above sea level. That is close enough that the station's summers are Cheyenne's summers.

No other city in this set uses Cheyenne, so this sizing is Cheyenne's alone.

The sun over Cheyenne in late July

At 41.13°N, the noon sun on 21 July stands 69.3° above the horizon over Cheyenne and the day runs 14 h 32 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

65,704 people live in Cheyenne, the largest of the 11 Wyoming cities sized on this site. Coordinates used: 41.1283, -104.7992.

Cheyenne AC sizing questions

What size AC does a 2,000 sq ft house in Cheyenne, WY need?

About 2.5 tons, for a cooling load of 26,200 BTU/hr on a 89°F design day. That is one ton per 916 square feet in Cheyenne's climate.

Is 20 BTU per square foot right for Cheyenne?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Cheyenne. For a single room here, plan on 13.1 BTU/hr per square foot.

What does central AC cost to run in Cheyenne?

About $70 a year: 501 kWh at SEER2 14.3 and 14.01¢ per kWh, over 3 cooling months.