What size AC for Timnath, CO? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Timnath needs
2.5 tons central AC or heat pump, about 29,200 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 44% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 822 square feet in this climate. For a single room, size by the room: 14.6 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Fort Collins 4 E (4.1 mi away). Jul is the hottest month, averaging a high of 87.6°F and a low of 57.7°F, with about 32 days a year at 90°F or more. That gives a design temperature of 93°F against 75°F inside.
What it costs to run
About 734 kWh a year at SEER2 14.3, or roughly $123 at Colorado's average residential rate of 16.8¢ per kWh. Cooling runs 3 months of the year here.
What drives the load in Timnath
Of the 29,200 BTU/hr, 12,960 comes through walls, roof and windows on a 93°F afternoon (44%), 13,000 is sun on the house (45%), 2,120 is four people and their appliances, and 1,100 is moisture the coil has to wring out of Timnath's summer air (4%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 28,080 BTU/hr before the moisture allowance.
Other house sizes in Timnath
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 15,700 | 1.5 tons | 2 tons |
| 1,500 sq ft | 22,500 | 2 tons | 2.5 tons |
| 2,500 sq ft | 36,000 | 3 tons | 5 tons |
| 3,000 sq ft | 42,700 | 4 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,100 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,800 BTU/hr.
Month by month in Timnath
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 42.6°F | 0 | 0 |
| Feb | 44.9°F | 0 | 0 |
| Mar | 55°F | 0 | 0 |
| Apr | 61.1°F | 0 | 0 |
| May | 69.9°F | 13 | 16 |
| Jun | 81.4°F | 106 | 133 |
| Jul | 87.6°F | 242 | 304 |
| Aug | 85.1°F | 177 | 222 |
| Sep | 77.1°F | 46 | 58 |
| Oct | 63.4°F | 0 | 1 |
| Nov | 51°F | 0 | 0 |
| Dec | 42.1°F | 0 | 0 |
Jul alone uses 41% of the year's cooling energy. The unit runs the equivalent of 359 hours a year at full output.
Timnath against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Windsor, CO | 5 mi | 93°F | 2.5 tons |
| Fort Collins, CO | 5 mi | 92°F | 2.5 tons |
| Severance, CO | 6 mi | 92°F | 2.5 tons |
| Loveland, CO | 10 mi | 94°F | 2.5 tons |
| Wellington, CO | 11 mi | 92°F | 2.5 tons |
| Greeley, CO | 13 mi | 98°F | 3 tons |
Of 53 Colorado cities here, Timnath has the 45th highest cooling load. The range runs from Boulder at 15,700 BTU/hr to Grand Junction at 36,500.
Where Timnath's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Fort Collins 4 E, 4.1 miles from the center of Timnath at 4,920 ft above sea level. That is close enough that the station's summers are Timnath's summers.
1 other city uses the same station and get the same climate inputs. The closest to Timnath: Windsor (5 mi away, 8.8 mi from the station). Timnath sits closer to the station than any of them, so its numbers are the best measured of the group.
The sun over Timnath in late July
At 40.54°N, the noon sun on 21 July stands 69.9° above the horizon over Timnath and the day runs 14 h 28 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
10,848 people live in Timnath, the 51st largest of the 53 Colorado cities sized on this site. Coordinates used: 40.5359, -104.9644.
Timnath AC sizing questions
What size AC does a 2,000 sq ft house in Timnath, CO need?
About 2.5 tons, for a cooling load of 29,200 BTU/hr on a 93°F design day. That is one ton per 822 square feet in Timnath's climate.
Is 20 BTU per square foot right for Timnath?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Fort Collins 4 E. For a single room here, plan on 14.6 BTU/hr per square foot.
What does central AC cost to run in Timnath?
About $123 a year: 734 kWh at SEER2 14.3 and 16.8¢ per kWh, over 3 cooling months.