What size AC for Cheney, WA? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Cheney needs
2.5 tons central AC or heat pump, about 26,200 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 60% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 916 square feet in this climate. For a single room, size by the room: 13.1 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Spokane 17 Ssw (5.7 mi away). Jul is the hottest month, averaging a high of 84.1°F and a low of 44.7°F, with about 20 days a year at 90°F or more. That gives a design temperature of 89°F against 75°F inside.
What it costs to run
About 157 kWh a year at SEER2 14.3, or roughly $23 at Washington's average residential rate of 14.42¢ per kWh. Cooling runs 1 month of the year here.
What drives the load in Cheney
Of the 26,200 BTU/hr, 10,080 comes through walls, roof and windows on a 89°F afternoon (38%), 13,000 is sun on the house (50%), 2,120 is four people and their appliances, and 1,000 is moisture the coil has to wring out of Cheney's summer air (4%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,200 BTU/hr before the moisture allowance.
Other house sizes in Cheney
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 14,200 | 1.5 tons | 2 tons |
| 1,500 sq ft | 20,200 | 2 tons | 2.5 tons |
| 2,500 sq ft | 32,200 | 3 tons | 5 tons |
| 3,000 sq ft | 38,200 | 3.5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,900 BTU/hr.
Month by month in Cheney
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 35.7°F | 0 | 0 |
| Feb | 40.4°F | 0 | 0 |
| Mar | 49.2°F | 0 | 0 |
| Apr | 56.7°F | 0 | 0 |
| May | 66.6°F | 1 | 1 |
| Jun | 72.6°F | 9 | 11 |
| Jul | 84.1°F | 64 | 80 |
| Aug | 83.9°F | 47 | 59 |
| Sep | 74.4°F | 5 | 6 |
| Oct | 58.7°F | 0 | 0 |
| Nov | 43.3°F | 0 | 0 |
| Dec | 35°F | 0 | 0 |
Jul alone uses 51% of the year's cooling energy. The unit runs the equivalent of 86 hours a year at full output.
Cheney against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Airway Heights, WA | 11 mi | 89°F | 2.5 tons |
| Spokane, WA | 14 mi | 92°F | 2.5 tons |
| Spokane Valley, WA | 20 mi | 92°F | 2.5 tons |
| Liberty Lake, WA | 25 mi | 92°F | 2.5 tons |
| Post Falls, ID | 34 mi | 92°F | 2.5 tons |
| Rathdrum, ID | 38 mi | 92°F | 2.5 tons |
Of 91 Washington cities here, Cheney has the 16th highest cooling load. The range runs from Burlington at 15,700 BTU/hr to Kennewick at 32,900.
Where Cheney's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Spokane 17 Ssw, 5.7 miles from the center of Cheney at 2,267 ft above sea level. That is close enough that the station's summers are Cheney's summers.
No other city in this set uses Spokane 17 Ssw, so this sizing is Cheney's alone.
The sun over Cheney in late July
At 47.49°N, the noon sun on 21 July stands 62.9° above the horizon over Cheney and the day runs 15 h 11 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
12,700 people live in Cheney, the 80th largest of the 91 Washington cities sized on this site. Coordinates used: 47.4911, -117.5815.
Cheney AC sizing questions
What size AC does a 2,000 sq ft house in Cheney, WA need?
About 2.5 tons, for a cooling load of 26,200 BTU/hr on a 89°F design day. That is one ton per 916 square feet in Cheney's climate.
Is 20 BTU per square foot right for Cheney?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Spokane 17 Ssw. For a single room here, plan on 13.1 BTU/hr per square foot.
What does central AC cost to run in Cheney?
About $23 a year: 157 kWh at SEER2 14.3 and 14.42¢ per kWh, over 1 cooling month.