ACSizeCheck

What size AC for Post Falls, ID? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Post Falls needs

2.5 tons central AC or heat pump, about 28,500 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 48% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 843 square feet in this climate. For a single room, size by the room: 14.2 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Spokane Felts Field (17.8 mi away). Jul is the hottest month, averaging a high of 87.1°F and a low of 56°F, with about 29 days a year at 90°F or more. That gives a design temperature of 92°F against 75°F inside.

What it costs to run

About 637 kWh a year at SEER2 14.3, or roughly $83 at Idaho's average residential rate of 13.02¢ per kWh. Cooling runs 3 months of the year here.

What drives the load in Post Falls

Of the 28,500 BTU/hr, 12,240 comes through walls, roof and windows on a 92°F afternoon (43%), 13,000 is sun on the house (46%), 2,120 is four people and their appliances, and 1,100 is moisture the coil has to wring out of Post Falls's summer air (4%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 27,360 BTU/hr before the moisture allowance.

Other house sizes in Post Falls

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft15,3001.5 tons2 tons
1,500 sq ft21,9002 tons2.5 tons
2,500 sq ft35,0003 tons5 tons
3,000 sq ft41,6003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,100 BTU/hr; a 350 sq ft living room needs about 5,000 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,500 BTU/hr.

Month by month in Post Falls

MonthAvg highCooling degree daysAC kWh
Jan37.8°F00
Feb42.5°F00
Mar51.3°F00
Apr59.6°F00
May69.7°F1417
Jun75.8°F5367
Jul87.1°F218274
Aug86.2°F184231
Sep76°F3847
Oct60.3°F11
Nov45.1°F00
Dec36.9°F00

Jul alone uses 43% of the year's cooling energy. The unit runs the equivalent of 320 hours a year at full output.

Post Falls against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Rathdrum, ID5 mi92°F2.5 tons
Coeur d'Alene, ID7 mi88°F2 tons
Hayden, ID7 mi88°F2 tons
Liberty Lake, WA8 mi92°F2.5 tons
Spokane Valley, WA14 mi92°F2.5 tons
Spokane, WA23 mi92°F2.5 tons

Of 26 Idaho cities here, Post Falls has the 17th highest cooling load. The range runs from Sandpoint at 24,000 BTU/hr to Mountain Home at 36,500.

Where Post Falls's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Spokane Felts Field, across the line in Washington, 17.8 miles from the center of Post Falls at 1,951 ft above sea level. That is close enough that the station's summers are Post Falls's summers.

4 other cities use the same station and get the same climate inputs. The closest to Post Falls: Rathdrum (5 mi away, 21.3 mi from the station), Liberty Lake (8 mi away, 10.2 mi from the station), Spokane Valley (14 mi away, 4.4 mi from the station), Spokane (23 mi away, 5.4 mi from the station). Post Falls is farther from the station than 3 of them.

The sun over Post Falls in late July

At 47.73°N, the noon sun on 21 July stands 62.7° above the horizon over Post Falls and the day runs 15 h 13 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

45,800 people live in Post Falls, the 9th largest of the 26 Idaho cities sized on this site. Coordinates used: 47.7256, -116.9442.

Post Falls AC sizing questions

What size AC does a 2,000 sq ft house in Post Falls, ID need?

About 2.5 tons, for a cooling load of 28,500 BTU/hr on a 92°F design day. That is one ton per 843 square feet in Post Falls's climate.

Is 20 BTU per square foot right for Post Falls?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Spokane Felts Field. For a single room here, plan on 14.2 BTU/hr per square foot.

What does central AC cost to run in Post Falls?

About $83 a year: 637 kWh at SEER2 14.3 and 13.02¢ per kWh, over 3 cooling months.