ACSizeCheck

What size AC for Beeville, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Beeville needs

4 tons central AC or heat pump, about 46,800 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, which falls short here. On a design day the unit runs flat out and the house still drifts above 75°F by late afternoon.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 513 square feet in this climate. For a single room, size by the room: 23.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Beeville 5 Ne (4.5 mi away). Aug is the hottest month, averaging a high of 95.7°F and a low of 73.4°F, with about 123 days a year at 90°F or more. That gives a design temperature of 104°F against 75°F inside.

What it costs to run

About 5,059 kWh a year at SEER2 14.3, or roughly $811 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 9 months of the year here.

What drives the load in Beeville

Of the 46,800 BTU/hr, 20,880 comes through walls, roof and windows on a 104°F afternoon (45%), 13,000 is sun on the house (28%), 2,120 is four people and their appliances, and 10,800 is moisture the coil has to wring out of Beeville's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,000 BTU/hr before the moisture allowance.

Other house sizes in Beeville

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft24,8002 tons2 tons
1,500 sq ft35,8003 tons2.5 tons
2,500 sq ft57,8005 tons5 tons
3,000 sq ft68,8005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,500 BTU/hr; a 350 sq ft living room needs about 8,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 14,000 BTU/hr.

Month by month in Beeville

MonthAvg highCooling degree daysAC kWh
Jan65.5°F1828
Feb69°F3250
Mar74.6°F89140
Apr80.7°F184289
May86.8°F377592
Jun91.9°F511803
Jul93.8°F575903
Aug95.7°F606952
Sep90.4°F449706
Oct84.1°F262411
Nov74.9°F91142
Dec67.2°F2742

Aug alone uses 19% of the year's cooling energy. The unit runs the equivalent of 1,546 hours a year at full output.

Beeville against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Robstown, TX43 mi103°F4 tons
Portland, TX44 mi103°F4 tons
Alice, TX49 mi106°F4 tons
Rockport, TX49 mi100°F4 tons
Ingleside, TX50 mi101°F4 tons
Victoria, TX55 mi104°F4 tons

Of 252 Texas cities here, Beeville has the 106th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Beeville's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Beeville 5 Ne, 4.5 miles from the center of Beeville at 255 ft above sea level. That is close enough that the station's summers are Beeville's summers.

No other city in this set uses Beeville 5 Ne, so this sizing is Beeville's alone.

The sun over Beeville in late July

At 28.41°N, the noon sun on 21 July stands 82.0° above the horizon over Beeville and the day runs 13 h 33 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.

13,176 people live in Beeville, the 210th largest of the 252 Texas cities sized on this site. Coordinates used: 28.4052, -97.7489.

Beeville AC sizing questions

What size AC does a 2,000 sq ft house in Beeville, TX need?

About 4 tons, for a cooling load of 46,800 BTU/hr on a 104°F design day. That is one ton per 513 square feet in Beeville's climate.

Is 20 BTU per square foot right for Beeville?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Beeville 5 Ne. For a single room here, plan on 23.4 BTU/hr per square foot.

What does central AC cost to run in Beeville?

About $811 a year: 5,059 kWh at SEER2 14.3 and 16.03¢ per kWh, over 9 cooling months.