ACSizeCheck

What size AC for Beatrice, NE? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Beatrice needs

3 tons central AC or heat pump, about 33,100 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 27% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 725 square feet in this climate. For a single room, size by the room: 16.6 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Beatrice 1n (1.8 mi away). Jul is the hottest month, averaging a high of 88.4°F and a low of 65.5°F, with about 40 days a year at 90°F or more. That gives a design temperature of 94°F against 75°F inside.

What it costs to run

About 1,577 kWh a year at SEER2 14.3, or roughly $204 at Nebraska's average residential rate of 12.92¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Beatrice

Of the 33,100 BTU/hr, 13,680 comes through walls, roof and windows on a 94°F afternoon (41%), 13,000 is sun on the house (39%), 2,120 is four people and their appliances, and 4,300 is moisture the coil has to wring out of Beatrice's summer air (13%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 28,800 BTU/hr before the moisture allowance.

Other house sizes in Beatrice

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft17,8001.5 tons2 tons
1,500 sq ft25,4002 tons2.5 tons
2,500 sq ft40,8003.5 tons5 tons
3,000 sq ft48,5004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,500 BTU/hr; a 350 sq ft living room needs about 5,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,000 BTU/hr.

Month by month in Beatrice

MonthAvg highCooling degree daysAC kWh
Jan34.9°F00
Feb40°F00
Mar52.3°F12
Apr63.3°F710
May73.5°F6691
Jun83.7°F241335
Jul88.4°F372517
Aug86.3°F305424
Sep79.4°F124172
Oct66.6°F1724
Nov51.2°F11
Dec39°F00

Jul alone uses 33% of the year's cooling energy. The unit runs the equivalent of 681 hours a year at full output.

Beatrice against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Lincoln, NE37 mi95°F3 tons
Papillion, NE70 mi90°F2.5 tons
La Vista, NE72 mi90°F2.5 tons
Bellevue, NE74 mi93°F3 tons
Manhattan, KS75 mi97°F3.5 tons
Omaha, NE77 mi90°F2.5 tons

Of 16 Nebraska cities here, Beatrice has the 3rd highest cooling load. The range runs from South Sioux City at 28,000 BTU/hr to Bellevue at 34,300.

Where Beatrice's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Beatrice 1n, 1.8 miles from the center of Beatrice at 1,297 ft above sea level. That is close enough that the station's summers are Beatrice's summers.

No other city in this set uses Beatrice 1n, so this sizing is Beatrice's alone.

The sun over Beatrice in late July

At 40.27°N, the noon sun on 21 July stands 70.1° above the horizon over Beatrice and the day runs 14 h 27 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

12,290 people live in Beatrice, the 15th largest of the 16 Nebraska cities sized on this site. Coordinates used: 40.2733, -96.7460.

Beatrice AC sizing questions

What size AC does a 2,000 sq ft house in Beatrice, NE need?

About 3 tons, for a cooling load of 33,100 BTU/hr on a 94°F design day. That is one ton per 725 square feet in Beatrice's climate.

Is 20 BTU per square foot right for Beatrice?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Beatrice 1n. For a single room here, plan on 16.6 BTU/hr per square foot.

What does central AC cost to run in Beatrice?

About $204 a year: 1,577 kWh at SEER2 14.3 and 12.92¢ per kWh, over 5 cooling months.