What size AC for Athens, OH? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Athens needs

2 tons central AC or heat pump, about 25,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 64% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 935 square feet in this climate. For a single room, size by the room: 12.8 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Athens Ou (0.3 mi away). Jul is the hottest month, averaging a high of 82.4°F and a low of 63°F, with about 11 days a year at 90°F or more. That gives a design temperature of 87°F against 75°F inside.

What it costs to run

About 1,001 kWh a year at SEER2 14.3, or roughly $188 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Athens

Of the 25,700 BTU/hr, 8,640 comes through walls, roof and windows on a 87°F afternoon (34%), 13,000 is sun on the house (51%), 2,120 is four people and their appliances, and 1,900 is moisture the coil has to wring out of Athens's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,760 BTU/hr before the moisture allowance.

Other house sizes in Athens

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,0001.5 tons2 tons
1,500 sq ft19,8001.5 tons2.5 tons
2,500 sq ft31,5003 tons5 tons
3,000 sq ft37,3003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,700 BTU/hr.

Month by month in Athens

MonthAvg highCooling degree daysAC kWh
Jan38°F00
Feb42.2°F00
Mar52.2°F22
Apr65.2°F1114
May72.3°F5065
Jun79.5°F158206
Jul82.4°F241315
Aug81.5°F207270
Sep76.2°F85111
Oct65.2°F1418
Nov53.2°F00
Dec42.6°F00

Jul alone uses 31% of the year's cooling energy. The unit runs the equivalent of 558 hours a year at full output.

Athens against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Parkersburg, WV30 mi92°F3 tons
Vienna, WV30 mi92°F3 tons
Marietta, OH36 mi90°F2.5 tons
Lancaster, OH39 mi89°F2.5 tons
Zanesville, OH44 mi89°F2.5 tons
Chillicothe, OH48 mi90°F2.5 tons

Of 176 Ohio cities here, Athens has the 144th highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.

Where Athens's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Athens Ou, 0.3 miles from the center of Athens at 684 ft above sea level. That is close enough that the station's summers are Athens's summers.

No other city in this set uses Athens Ou, so this sizing is Athens's alone.

The sun over Athens in late July

At 39.33°N, the noon sun on 21 July stands 71.1° above the horizon over Athens and the day runs 14 h 22 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

24,824 people live in Athens, the 65th largest of the 176 Ohio cities sized on this site. Coordinates used: 39.3263, -82.1002.

Athens AC sizing questions

What size AC does a 2,000 sq ft house in Athens, OH need?

About 2 tons, for a cooling load of 25,700 BTU/hr on a 87°F design day. That is one ton per 935 square feet in Athens's climate.

Is 20 BTU per square foot right for Athens?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Athens Ou. For a single room here, plan on 12.8 BTU/hr per square foot.

What does central AC cost to run in Athens?

About $188 a year: 1,001 kWh at SEER2 14.3 and 18.81¢ per kWh, over 5 cooling months.