What size AC for Zanesville, OH? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Zanesville needs

2.5 tons central AC or heat pump, about 27,200 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 54% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 882 square feet in this climate. For a single room, size by the room: 13.6 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Zanesville Municipal Airport (6.3 mi away). Jul is the hottest month, averaging a high of 84.8°F and a low of 63.6°F, with about 13 days a year at 90°F or more. That gives a design temperature of 89°F against 75°F inside.

What it costs to run

About 1,192 kWh a year at SEER2 14.3, or roughly $224 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Zanesville

Of the 27,200 BTU/hr, 10,080 comes through walls, roof and windows on a 89°F afternoon (37%), 13,000 is sun on the house (48%), 2,120 is four people and their appliances, and 2,000 is moisture the coil has to wring out of Zanesville's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,200 BTU/hr before the moisture allowance.

Other house sizes in Zanesville

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,8001.5 tons2 tons
1,500 sq ft21,0002 tons2.5 tons
2,500 sq ft33,4003 tons5 tons
3,000 sq ft39,7003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,200 BTU/hr.

Month by month in Zanesville

MonthAvg highCooling degree daysAC kWh
Jan38.4°F00
Feb42°F00
Mar52°F12
Apr64.6°F1013
May73.8°F6788
Jun81.4°F187244
Jul84.8°F287374
Aug83.7°F243317
Sep77.5°F103135
Oct65.6°F1418
Nov53.2°F00
Dec42.5°F00

Jul alone uses 31% of the year's cooling energy. The unit runs the equivalent of 626 hours a year at full output.

Zanesville against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Coshocton, OH23 mi88°F2.5 tons
Cambridge, OH23 mi90°F2.5 tons
Heath, OH23 mi91°F2.5 tons
Newark, OH23 mi91°F2.5 tons
Lancaster, OH35 mi89°F2.5 tons
Pataskala, OH38 mi90°F2.5 tons

Of 176 Ohio cities here, Zanesville has the 111th highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.

Where Zanesville's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Zanesville Municipal Airport, 6.3 miles from the center of Zanesville at 881 ft above sea level. That is close enough that the station's summers are Zanesville's summers.

No other city in this set uses Zanesville Municipal Airport, so this sizing is Zanesville's alone.

The sun over Zanesville in late July

At 39.96°N, the noon sun on 21 July stands 70.4° above the horizon over Zanesville and the day runs 14 h 25 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

24,916 people live in Zanesville, the 64th largest of the 176 Ohio cities sized on this site. Coordinates used: 39.9570, -82.0120.

Zanesville AC sizing questions

What size AC does a 2,000 sq ft house in Zanesville, OH need?

About 2.5 tons, for a cooling load of 27,200 BTU/hr on a 89°F design day. That is one ton per 882 square feet in Zanesville's climate.

Is 20 BTU per square foot right for Zanesville?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Zanesville Municipal Airport. For a single room here, plan on 13.6 BTU/hr per square foot.

What does central AC cost to run in Zanesville?

About $224 a year: 1,192 kWh at SEER2 14.3 and 18.81¢ per kWh, over 5 cooling months.