ACSizeCheck

What size AC for Ada, OK? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Ada needs

3.5 tons central AC or heat pump, about 40,400 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.4 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 594 square feet in this climate. For a single room, size by the room: 20.2 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Ada (1.6 mi away). Jul is the hottest month, averaging a high of 93.8°F and a low of 71.9°F, with about 70 days a year at 90°F or more. That gives a design temperature of 100°F against 75°F inside.

What it costs to run

About 3,004 kWh a year at SEER2 14.3, or roughly $415 at Oklahoma's average residential rate of 13.81¢ per kWh. Cooling runs 6 months of the year here.

What drives the load in Ada

Of the 40,400 BTU/hr, 18,000 comes through walls, roof and windows on a 100°F afternoon (45%), 13,000 is sun on the house (32%), 2,120 is four people and their appliances, and 7,300 is moisture the coil has to wring out of Ada's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,120 BTU/hr before the moisture allowance.

Other house sizes in Ada

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft21,5002 tons2 tons
1,500 sq ft31,0002.5 tons2.5 tons
2,500 sq ft49,9004 tons5 tons
3,000 sq ft59,3005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,000 BTU/hr; a 350 sq ft living room needs about 7,100 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,100 BTU/hr.

Month by month in Ada

MonthAvg highCooling degree daysAC kWh
Jan51.6°F00
Feb57°F11
Mar65.3°F69
Apr73.3°F3653
May80.4°F168247
Jun88.6°F397585
Jul93.8°F553816
Aug93.6°F524772
Sep85.7°F281414
Oct75.4°F6595
Nov64°F811
Dec53.9°F00

Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 1,063 hours a year at full output.

Ada against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Shawnee, OK45 mi99°F3.5 tons
Ardmore, OK47 mi102°F4 tons
Norman, OK50 mi100°F3.5 tons
McAlester, OK52 mi100°F4 tons
Durant, OK56 mi102°F4 tons
Moore, OK60 mi100°F3.5 tons

Of 45 Oklahoma cities here, Ada has the 35th highest cooling load. The range runs from Miami at 35,600 BTU/hr to Ardmore at 44,900.

Where Ada's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Ada, 1.6 miles from the center of Ada at 1,015 ft above sea level. That is close enough that the station's summers are Ada's summers.

No other city in this set uses Ada, so this sizing is Ada's alone.

The sun over Ada in late July

At 34.77°N, the noon sun on 21 July stands 75.6° above the horizon over Ada and the day runs 13 h 60 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

16,578 people live in Ada, the 33rd largest of the 45 Oklahoma cities sized on this site. Coordinates used: 34.7679, -96.6691.

Ada AC sizing questions

What size AC does a 2,000 sq ft house in Ada, OK need?

About 3.5 tons, for a cooling load of 40,400 BTU/hr on a 100°F design day. That is one ton per 594 square feet in Ada's climate.

Is 20 BTU per square foot right for Ada?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Ada. For a single room here, plan on 20.2 BTU/hr per square foot.

What does central AC cost to run in Ada?

About $415 a year: 3,004 kWh at SEER2 14.3 and 13.81¢ per kWh, over 6 cooling months.