ACSizeCheck

What size AC for Moore, OK? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Moore needs

3.5 tons central AC or heat pump, about 40,400 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.4 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 594 square feet in this climate. For a single room, size by the room: 20.2 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Oklahoma Cy Will Rogers World (8.2 mi away). Jul is the hottest month, averaging a high of 93.1°F and a low of 70.3°F, with about 73 days a year at 90°F or more. That gives a design temperature of 100°F against 75°F inside.

What it costs to run

About 2,753 kWh a year at SEER2 14.3, or roughly $380 at Oklahoma's average residential rate of 13.81¢ per kWh. Cooling runs 6 months of the year here.

What drives the load in Moore

Of the 40,400 BTU/hr, 18,000 comes through walls, roof and windows on a 100°F afternoon (45%), 13,000 is sun on the house (32%), 2,120 is four people and their appliances, and 7,300 is moisture the coil has to wring out of Moore's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,120 BTU/hr before the moisture allowance.

Other house sizes in Moore

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft21,5002 tons2 tons
1,500 sq ft31,0002.5 tons2.5 tons
2,500 sq ft49,9004 tons5 tons
3,000 sq ft59,3005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,000 BTU/hr; a 350 sq ft living room needs about 7,100 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,100 BTU/hr.

Month by month in Moore

MonthAvg highCooling degree daysAC kWh
Jan49.3°F00
Feb53.8°F12
Mar62.9°F914
Apr71.1°F3551
May78.9°F151223
Jun87.5°F357526
Jul93.1°F518763
Aug92.2°F485715
Sep83.9°F251370
Oct72.8°F5683
Nov60.7°F46
Dec50.4°F00

Jul alone uses 28% of the year's cooling energy. The unit runs the equivalent of 974 hours a year at full output.

Moore against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Del City, OK8 mi100°F3.5 tons
Newcastle, OK9 mi100°F3.5 tons
Norman, OK9 mi100°F3.5 tons
Oklahoma City, OK10 mi100°F3.5 tons
Midwest City, OK11 mi100°F3.5 tons
Mustang, OK15 mi100°F3.5 tons

Of 45 Oklahoma cities here, Moore has the 27th highest cooling load. The range runs from Miami at 35,600 BTU/hr to Ardmore at 44,900.

Where Moore's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Oklahoma Cy Will Rogers World, 8.2 miles from the center of Moore at 1,279 ft above sea level. That is close enough that the station's summers are Moore's summers.

7 other cities use the same station and get the same climate inputs. The closest to Moore: Del City (8 mi away, 9.9 mi from the station), Newcastle (9 mi away, 10.1 mi from the station), Norman (9 mi away, 17.6 mi from the station), Oklahoma City (10 mi away, 7.3 mi from the station), Midwest City (11 mi away, 13.6 mi from the station). Moore is farther from the station than 2 of them.

The sun over Moore in late July

At 35.33°N, the noon sun on 21 July stands 75.1° above the horizon over Moore and the day runs 14 h 02 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

63,845 people live in Moore, the 7th largest of the 45 Oklahoma cities sized on this site. Coordinates used: 35.3285, -97.4748.

Moore AC sizing questions

What size AC does a 2,000 sq ft house in Moore, OK need?

About 3.5 tons, for a cooling load of 40,400 BTU/hr on a 100°F design day. That is one ton per 594 square feet in Moore's climate.

Is 20 BTU per square foot right for Moore?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Oklahoma Cy Will Rogers World. For a single room here, plan on 20.2 BTU/hr per square foot.

What does central AC cost to run in Moore?

About $380 a year: 2,753 kWh at SEER2 14.3 and 13.81¢ per kWh, over 6 cooling months.