ACSizeCheck

What size AC for Aberdeen, WA? 1.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Aberdeen needs

1.5 tons central AC or heat pump, about 15,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 167% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 1.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 1,526 square feet in this climate. For a single room, size by the room: 7.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Hoquiam Bowerman Airport (5.6 mi away). Aug is the hottest month, averaging a high of 68.1°F and a low of 53.9°F, with about 1 day a year at 90°F or more. That gives a design temperature of 72°F against 75°F inside.

What it costs to run

About 32 kWh a year at SEER2 14.3, or roughly $5 at Washington's average residential rate of 14.42¢ per kWh. Cooling runs 0 months of the year here.

What drives the load in Aberdeen

Of the 15,700 BTU/hr, 0 comes through walls, roof and windows on a 72°F afternoon (0%), 13,000 is sun on the house (83%), 2,120 is four people and their appliances, and 600 is moisture the coil has to wring out of Aberdeen's summer air (4%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 15,120 BTU/hr before the moisture allowance.

Other house sizes in Aberdeen

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft9,0001.5 tons2 tons
1,500 sq ft12,3001.5 tons2.5 tons
2,500 sq ft19,1001.5 tons5 tons
3,000 sq ft22,5002 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,200 BTU/hr; a 350 sq ft living room needs about 2,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 4,700 BTU/hr.

Month by month in Aberdeen

MonthAvg highCooling degree daysAC kWh
Jan47.5°F00
Feb49.6°F00
Mar52.2°F00
Apr55.6°F00
May60.1°F12
Jun63.4°F23
Jul67°F68
Aug68.1°F810
Sep67°F89
Oct59.5°F00
Nov51.6°F00
Dec46.7°F00

Aug alone uses 31% of the year's cooling energy. The unit runs the equivalent of 29 hours a year at full output.

Aberdeen against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Shelton, WA37 mi83°F2 tons
Tumwater, WA42 mi82°F2 tons
Centralia, WA43 mi82°F2 tons
Olympia, WA43 mi82°F2 tons
Lacey, WA48 mi82°F2 tons
Yelm, WA55 mi82°F2 tons

Of 91 Washington cities here, Aberdeen has the 90th highest cooling load. The range runs from Burlington at 15,700 BTU/hr to Kennewick at 32,900.

Where Aberdeen's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Hoquiam Bowerman Airport, 5.6 miles from the center of Aberdeen at 15 ft above sea level. That is close enough that the station's summers are Aberdeen's summers.

No other city in this set uses Hoquiam Bowerman Airport, so this sizing is Aberdeen's alone.

The sun over Aberdeen in late July

At 46.98°N, the noon sun on 21 July stands 63.4° above the horizon over Aberdeen and the day runs 15 h 08 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

17,044 people live in Aberdeen, the 65th largest of the 91 Washington cities sized on this site. Coordinates used: 46.9752, -123.8114.

Aberdeen AC sizing questions

What size AC does a 2,000 sq ft house in Aberdeen, WA need?

About 1.5 tons, for a cooling load of 15,700 BTU/hr on a 72°F design day. That is one ton per 1,526 square feet in Aberdeen's climate.

Is 20 BTU per square foot right for Aberdeen?

The chart gives 3.5 tons for 2,000 sq ft, against 1.5 tons sized from NOAA's 1991 to 2020 normals at Hoquiam Bowerman Airport. For a single room here, plan on 7.9 BTU/hr per square foot.

What does central AC cost to run in Aberdeen?

About $5 a year: 32 kWh at SEER2 14.3 and 14.42¢ per kWh, over 0 cooling months.