What size AC for Lacey, WA? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Lacey needs

2 tons central AC or heat pump, about 21,000 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 100% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 1,145 square feet in this climate. For a single room, size by the room: 10.5 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Olympia Airport (7 mi away). Aug is the hottest month, averaging a high of 78°F and a low of 50.5°F, with about 6 days a year at 90°F or more. That gives a design temperature of 82°F against 75°F inside.

What it costs to run

About 142 kWh a year at SEER2 14.3, or roughly $20 at Washington's average residential rate of 14.42¢ per kWh. Cooling runs 0 months of the year here.

What drives the load in Lacey

Of the 21,000 BTU/hr, 5,040 comes through walls, roof and windows on a 82°F afternoon (24%), 13,000 is sun on the house (62%), 2,120 is four people and their appliances, and 800 is moisture the coil has to wring out of Lacey's summer air (4%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 20,160 BTU/hr before the moisture allowance.

Other house sizes in Lacey

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft11,6001.5 tons2 tons
1,500 sq ft16,3001.5 tons2.5 tons
2,500 sq ft25,7002 tons5 tons
3,000 sq ft30,3002.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,600 BTU/hr; a 350 sq ft living room needs about 3,700 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 6,300 BTU/hr.

Month by month in Lacey

MonthAvg highCooling degree daysAC kWh
Jan46°F00
Feb49.1°F00
Mar53.7°F00
Apr58.9°F00
May66.1°F23
Jun70.8°F1216
Jul77.6°F4759
Aug78°F4455
Sep72.1°F810
Oct60.2°F00
Nov50.6°F00
Dec44.9°F00

Jul alone uses 42% of the year's cooling energy. The unit runs the equivalent of 97 hours a year at full output.

Lacey against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Olympia, WA5 mi82°F2 tons
Tumwater, WA7 mi82°F2 tons
Yelm, WA10 mi82°F2 tons
Lakewood, WA15 mi80°F1.5 tons
University Place, WA17 mi80°F1.5 tons
Shelton, WA19 mi83°F2 tons

Of 91 Washington cities here, Lacey has the 37th highest cooling load. The range runs from Burlington at 15,700 BTU/hr to Kennewick at 32,900.

Where Lacey's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Olympia Airport, 7 miles from the center of Lacey at 200 ft above sea level. That is close enough that the station's summers are Lacey's summers.

3 other cities use the same station and get the same climate inputs. The closest to Lacey: Olympia (5 mi away, 4.7 mi from the station), Tumwater (7 mi away, 1.2 mi from the station), Yelm (10 mi away, 12.5 mi from the station). Lacey is farther from the station than 2 of them.

The sun over Lacey in late July

At 47.04°N, the noon sun on 21 July stands 63.4° above the horizon over Lacey and the day runs 15 h 08 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

58,644 people live in Lacey, the 23rd largest of the 91 Washington cities sized on this site. Coordinates used: 47.0431, -122.7982.

Lacey AC sizing questions

What size AC does a 2,000 sq ft house in Lacey, WA need?

About 2 tons, for a cooling load of 21,000 BTU/hr on a 82°F design day. That is one ton per 1,145 square feet in Lacey's climate.

Is 20 BTU per square foot right for Lacey?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Olympia Airport. For a single room here, plan on 10.5 BTU/hr per square foot.

What does central AC cost to run in Lacey?

About $20 a year: 142 kWh at SEER2 14.3 and 14.42¢ per kWh, over 0 cooling months.