ACSizeCheck

What size AC for Worthington, MN? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Worthington needs

2 tons central AC or heat pump, about 24,900 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 69% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 965 square feet in this climate. For a single room, size by the room: 12.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Worthington 2 Nne (1.5 mi away). Jul is the hottest month, averaging a high of 82°F and a low of 60.8°F, with about 10 days a year at 90°F or more. That gives a design temperature of 86°F against 75°F inside.

What it costs to run

About 767 kWh a year at SEER2 14.3, or roughly $126 at Minnesota's average residential rate of 16.44¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Worthington

Of the 24,900 BTU/hr, 7,920 comes through walls, roof and windows on a 86°F afternoon (32%), 13,000 is sun on the house (52%), 2,120 is four people and their appliances, and 1,800 is moisture the coil has to wring out of Worthington's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,040 BTU/hr before the moisture allowance.

Other house sizes in Worthington

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft13,6001.5 tons2 tons
1,500 sq ft19,2001.5 tons2.5 tons
2,500 sq ft30,5002.5 tons5 tons
3,000 sq ft36,2003 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,400 BTU/hr.

Month by month in Worthington

MonthAvg highCooling degree daysAC kWh
Jan22.6°F00
Feb27.3°F00
Mar39.7°F00
Apr55.1°F22
May68°F3342
Jun78.4°F138180
Jul82°F212277
Aug79.4°F144188
Sep72.9°F5471
Oct58.9°F57
Nov41.8°F00
Dec27.9°F00

Jul alone uses 36% of the year's cooling energy. The unit runs the equivalent of 441 hours a year at full output.

Worthington against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Spencer, IA40 mi89°F2.5 tons
Brandon, SD49 mi90°F2.5 tons
Fairmont, MN57 mi87°F2 tons
Sioux Falls, SD57 mi90°F2.5 tons
Harrisburg, SD57 mi90°F2.5 tons
Marshall, MN57 mi89°F2.5 tons

Of 103 Minnesota cities here, Worthington has the 86th highest cooling load. The range runs from Hibbing at 20,200 BTU/hr to Winona at 29,000.

Where Worthington's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Worthington 2 Nne, 1.5 miles from the center of Worthington at 1,570 ft above sea level. That is close enough that the station's summers are Worthington's summers.

No other city in this set uses Worthington 2 Nne, so this sizing is Worthington's alone.

The sun over Worthington in late July

At 43.63°N, the noon sun on 21 July stands 66.8° above the horizon over Worthington and the day runs 14 h 46 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

13,754 people live in Worthington, the 86th largest of the 103 Minnesota cities sized on this site. Coordinates used: 43.6287, -95.5997.

Worthington AC sizing questions

What size AC does a 2,000 sq ft house in Worthington, MN need?

About 2 tons, for a cooling load of 24,900 BTU/hr on a 86°F design day. That is one ton per 965 square feet in Worthington's climate.

Is 20 BTU per square foot right for Worthington?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Worthington 2 Nne. For a single room here, plan on 12.4 BTU/hr per square foot.

What does central AC cost to run in Worthington?

About $126 a year: 767 kWh at SEER2 14.3 and 16.44¢ per kWh, over 4 cooling months.