ACSizeCheck

What size AC for Woodstock, GA? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Woodstock needs

3 tons central AC or heat pump, about 36,000 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 17% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 666 square feet in this climate. For a single room, size by the room: 18 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Cartersville Airport (19.3 mi away). Jul is the hottest month, averaging a high of 89.6°F and a low of 68°F, with about 55 days a year at 90°F or more. That gives a design temperature of 95°F against 75°F inside.

What it costs to run

About 2,399 kWh a year at SEER2 14.3, or roughly $371 at Georgia's average residential rate of 15.48¢ per kWh. Cooling runs 6 months of the year here.

What drives the load in Woodstock

Of the 36,000 BTU/hr, 14,400 comes through walls, roof and windows on a 95°F afternoon (40%), 13,000 is sun on the house (36%), 2,120 is four people and their appliances, and 6,500 is moisture the coil has to wring out of Woodstock's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 29,520 BTU/hr before the moisture allowance.

Other house sizes in Woodstock

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft19,3001.5 tons2 tons
1,500 sq ft27,7002.5 tons2.5 tons
2,500 sq ft44,4004 tons5 tons
3,000 sq ft52,7005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,700 BTU/hr; a 350 sq ft living room needs about 6,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,800 BTU/hr.

Month by month in Woodstock

MonthAvg highCooling degree daysAC kWh
Jan52.2°F00
Feb56.8°F11
Mar64.9°F68
Apr73.4°F3145
May80.7°F146216
Jun86.9°F317468
Jul89.6°F428631
Aug89.1°F408601
Sep84.2°F236348
Oct74°F5074
Nov62.9°F57
Dec54.5°F11

Jul alone uses 26% of the year's cooling energy. The unit runs the equivalent of 953 hours a year at full output.

Woodstock against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Holly Springs, GA5 mi95°F3 tons
Kennesaw, GA8 mi95°F3 tons
Acworth, GA10 mi95°F3 tons
Canton, GA10 mi95°F3 tons
Roswell, GA10 mi95°F3 tons
Marietta, GA10 mi96°F3.5 tons

Of 101 Georgia cities here, Woodstock has the 68th highest cooling load. The range runs from Cumming at 33,100 BTU/hr to Albany at 44,000.

Where Woodstock's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Cartersville Airport, 19.3 miles from the center of Woodstock at 755 ft above sea level. That is close enough that the station's summers are Woodstock's summers.

6 other cities use the same station and get the same climate inputs. The closest to Woodstock: Holly Springs (5 mi away, 21.2 mi from the station), Kennesaw (8 mi away, 14.7 mi from the station), Acworth (10 mi away, 10.4 mi from the station), Canton (10 mi away, 22.5 mi from the station), Cartersville (17 mi away, 4.4 mi from the station). Woodstock is farther from the station than 4 of them.

The sun over Woodstock in late July

At 34.10°N, the noon sun on 21 July stands 76.3° above the horizon over Woodstock and the day runs 13 h 57 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

39,381 people live in Woodstock, the 27th largest of the 101 Georgia cities sized on this site. Coordinates used: 34.1031, -84.5130.

Woodstock AC sizing questions

What size AC does a 2,000 sq ft house in Woodstock, GA need?

About 3 tons, for a cooling load of 36,000 BTU/hr on a 95°F design day. That is one ton per 666 square feet in Woodstock's climate.

Is 20 BTU per square foot right for Woodstock?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Cartersville Airport. For a single room here, plan on 18 BTU/hr per square foot.

What does central AC cost to run in Woodstock?

About $371 a year: 2,399 kWh at SEER2 14.3 and 15.48¢ per kWh, over 6 cooling months.