ACSizeCheck

What size AC for Winter Haven, FL? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Winter Haven needs

4 tons central AC or heat pump, about 44,000 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.7 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 546 square feet in this climate. For a single room, size by the room: 22 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Winter Haven Gilbert Airport (1.8 mi away). Jul is the hottest month, averaging a high of 92.9°F and a low of 75.4°F, with about 121 days a year at 90°F or more. That gives a design temperature of 101°F against 75°F inside.

What it costs to run

About 6,172 kWh a year at SEER2 14.3, or roughly $946 at Florida's average residential rate of 15.32¢ per kWh. Cooling runs 12 months of the year here.

What drives the load in Winter Haven

Of the 44,000 BTU/hr, 18,720 comes through walls, roof and windows on a 101°F afternoon (43%), 13,000 is sun on the house (30%), 2,120 is four people and their appliances, and 10,200 is moisture the coil has to wring out of Winter Haven's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,840 BTU/hr before the moisture allowance.

Other house sizes in Winter Haven

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft23,4002 tons2 tons
1,500 sq ft33,7003 tons2.5 tons
2,500 sq ft54,3005 tons5 tons
3,000 sq ft64,6005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,300 BTU/hr; a 350 sq ft living room needs about 7,700 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 13,200 BTU/hr.

Month by month in Winter Haven

MonthAvg highCooling degree daysAC kWh
Jan72.5°F6297
Feb75.6°F89139
Mar79.7°F165260
Apr84.6°F272427
May89.7°F445699
Jun92.2°F540848
Jul92.9°F594933
Aug92.7°F594932
Sep90.8°F523822
Oct86.1°F378593
Nov79.5°F174273
Dec74.4°F95149

Jul alone uses 15% of the year's cooling energy. The unit runs the equivalent of 2,006 hours a year at full output.

Winter Haven against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Auburndale, FL6 mi101°F4 tons
Haines City, FL8 mi101°F4 tons
Davenport, FL11 mi101°F4 tons
Lake Wales, FL12 mi101°F4 tons
Bartow, FL12 mi101°F4 tons
Lakeland, FL14 mi101°F4 tons

Of 173 Florida cities here, Winter Haven has the 6th highest cooling load. The range runs from Miami Shores at 36,500 BTU/hr to Plant City at 44,900.

Where Winter Haven's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Winter Haven Gilbert Airport, 1.8 miles from the center of Winter Haven at 143 ft above sea level. That is close enough that the station's summers are Winter Haven's summers.

6 other cities use the same station and get the same climate inputs. The closest to Winter Haven: Auburndale (6 mi away, 4.2 mi from the station), Haines City (8 mi away, 9.3 mi from the station), Davenport (11 mi away, 11.3 mi from the station), Lake Wales (12 mi away, 13.7 mi from the station), Bartow (12 mi away, 12.7 mi from the station). Winter Haven sits closer to the station than any of them, so its numbers are the best measured of the group.

The sun over Winter Haven in late July

At 28.05°N, the noon sun on 21 July stands 82.4° above the horizon over Winter Haven and the day runs 13 h 31 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.

59,975 people live in Winter Haven, the 53rd largest of the 173 Florida cities sized on this site. Coordinates used: 28.0458, -81.7327.

Winter Haven AC sizing questions

What size AC does a 2,000 sq ft house in Winter Haven, FL need?

About 4 tons, for a cooling load of 44,000 BTU/hr on a 101°F design day. That is one ton per 546 square feet in Winter Haven's climate.

Is 20 BTU per square foot right for Winter Haven?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Winter Haven Gilbert Airport. For a single room here, plan on 22 BTU/hr per square foot.

What does central AC cost to run in Winter Haven?

About $946 a year: 6,172 kWh at SEER2 14.3 and 15.32¢ per kWh, over 12 cooling months.