ACSizeCheck

What size AC for Winfield, KS? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Winfield needs

3.5 tons central AC or heat pump, about 38,700 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.2 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 621 square feet in this climate. For a single room, size by the room: 19.3 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Winfield Strother Field Airport (6.2 mi away). Jul is the hottest month, averaging a high of 91.9°F and a low of 70.5°F, with about 65 days a year at 90°F or more. That gives a design temperature of 98°F against 75°F inside.

What it costs to run

About 2,609 kWh a year at SEER2 14.3, or roughly $398 at Kansas's average residential rate of 15.26¢ per kWh. Cooling runs 6 months of the year here.

What drives the load in Winfield

Of the 38,700 BTU/hr, 16,560 comes through walls, roof and windows on a 98°F afternoon (43%), 13,000 is sun on the house (34%), 2,120 is four people and their appliances, and 7,000 is moisture the coil has to wring out of Winfield's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 31,680 BTU/hr before the moisture allowance.

Other house sizes in Winfield

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft20,6002 tons2 tons
1,500 sq ft29,6002.5 tons2.5 tons
2,500 sq ft47,7004 tons5 tons
3,000 sq ft56,7005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,900 BTU/hr; a 350 sq ft living room needs about 6,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,600 BTU/hr.

Month by month in Winfield

MonthAvg highCooling degree daysAC kWh
Jan45.6°F00
Feb50.7°F00
Mar60.4°F68
Apr69.3°F3044
May77.9°F135199
Jun87.4°F351517
Jul91.9°F502740
Aug91.1°F462681
Sep83.2°F231340
Oct71.3°F5074
Nov58.6°F45
Dec46.7°F00

Jul alone uses 28% of the year's cooling energy. The unit runs the equivalent of 965 hours a year at full output.

Winfield against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Arkansas City, KS12 mi98°F3.5 tons
Derby, KS27 mi99°F3.5 tons
Haysville, KS30 mi99°F3.5 tons
Andover, KS32 mi98°F3.5 tons
Ponca City, OK36 mi100°F3.5 tons
Wichita, KS37 mi99°F3.5 tons

Of 38 Kansas cities here, Winfield has the 10th highest cooling load. The range runs from Pittsburg at 33,100 BTU/hr to Wichita at 39,500.

Where Winfield's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Winfield Strother Field Airport, 6.2 miles from the center of Winfield at 1,152 ft above sea level. That is close enough that the station's summers are Winfield's summers.

1 other city uses the same station and get the same climate inputs. The closest to Winfield: Arkansas City (12 mi away, 6.3 mi from the station). Winfield sits closer to the station than any of them, so its numbers are the best measured of the group.

The sun over Winfield in late July

At 37.24°N, the noon sun on 21 July stands 73.2° above the horizon over Winfield and the day runs 14 h 11 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

11,678 people live in Winfield, the 31st largest of the 38 Kansas cities sized on this site. Coordinates used: 37.2428, -96.9797.

Winfield AC sizing questions

What size AC does a 2,000 sq ft house in Winfield, KS need?

About 3.5 tons, for a cooling load of 38,700 BTU/hr on a 98°F design day. That is one ton per 621 square feet in Winfield's climate.

Is 20 BTU per square foot right for Winfield?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Winfield Strother Field Airport. For a single room here, plan on 19.3 BTU/hr per square foot.

What does central AC cost to run in Winfield?

About $398 a year: 2,609 kWh at SEER2 14.3 and 15.26¢ per kWh, over 6 cooling months.