ACSizeCheck

What size AC for Winder, GA? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Winder needs

3 tons central AC or heat pump, about 33,900 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 24% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 707 square feet in this climate. For a single room, size by the room: 17 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Winder 4s (4.4 mi away). Jul is the hottest month, averaging a high of 89.4°F and a low of 67.7°F, with about 38 days a year at 90°F or more. That gives a design temperature of 95°F against 75°F inside.

What it costs to run

About 2,211 kWh a year at SEER2 14.3, or roughly $342 at Georgia's average residential rate of 15.48¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Winder

Of the 33,900 BTU/hr, 14,400 comes through walls, roof and windows on a 95°F afternoon (42%), 13,000 is sun on the house (38%), 2,120 is four people and their appliances, and 4,400 is moisture the coil has to wring out of Winder's summer air (13%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 29,520 BTU/hr before the moisture allowance.

Other house sizes in Winder

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft18,2001.5 tons2 tons
1,500 sq ft26,1002 tons2.5 tons
2,500 sq ft41,8003.5 tons5 tons
3,000 sq ft49,7004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,600 BTU/hr; a 350 sq ft living room needs about 6,000 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,200 BTU/hr.

Month by month in Winder

MonthAvg highCooling degree daysAC kWh
Jan53.9°F00
Feb57.5°F01
Mar66°F58
Apr73.6°F3042
May80.5°F139192
Jun86.7°F313436
Jul89.4°F420584
Aug88.6°F401558
Sep83°F229318
Oct73.6°F4664
Nov63.8°F79
Dec55.4°F01

Jul alone uses 26% of the year's cooling energy. The unit runs the equivalent of 932 hours a year at full output.

Winder against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Auburn, GA7 mi93°F3 tons
Braselton, GA10 mi93°F3 tons
Jefferson, GA12 mi93°F3 tons
Monroe, GA13 mi95°F3 tons
Loganville, GA15 mi95°F3 tons
Lawrenceville, GA16 mi95°F3 tons

Of 101 Georgia cities here, Winder has the 100th highest cooling load. The range runs from Cumming at 33,100 BTU/hr to Albany at 44,000.

Where Winder's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Winder 4s, 4.4 miles from the center of Winder at 889 ft above sea level. That is close enough that the station's summers are Winder's summers.

No other city in this set uses Winder 4s, so this sizing is Winder's alone.

The sun over Winder in late July

At 33.99°N, the noon sun on 21 July stands 76.4° above the horizon over Winder and the day runs 13 h 56 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

20,628 people live in Winder, the 54th largest of the 101 Georgia cities sized on this site. Coordinates used: 33.9916, -83.7236.

Winder AC sizing questions

What size AC does a 2,000 sq ft house in Winder, GA need?

About 3 tons, for a cooling load of 33,900 BTU/hr on a 95°F design day. That is one ton per 707 square feet in Winder's climate.

Is 20 BTU per square foot right for Winder?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Winder 4s. For a single room here, plan on 17 BTU/hr per square foot.

What does central AC cost to run in Winder?

About $342 a year: 2,211 kWh at SEER2 14.3 and 15.48¢ per kWh, over 5 cooling months.