ACSizeCheck

What size AC for Wildwood, FL? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Wildwood needs

4 tons central AC or heat pump, about 42,100 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.5 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 570 square feet in this climate. For a single room, size by the room: 21.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Leesburg Municipal Airport (12 mi away). Aug is the hottest month, averaging a high of 91.7°F and a low of 75°F, with about 108 days a year at 90°F or more. That gives a design temperature of 99°F against 75°F inside.

What it costs to run

About 5,469 kWh a year at SEER2 14.3, or roughly $838 at Florida's average residential rate of 15.32¢ per kWh. Cooling runs 11 months of the year here.

What drives the load in Wildwood

Of the 42,100 BTU/hr, 17,280 comes through walls, roof and windows on a 99°F afternoon (41%), 13,000 is sun on the house (31%), 2,120 is four people and their appliances, and 9,700 is moisture the coil has to wring out of Wildwood's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 32,400 BTU/hr before the moisture allowance.

Other house sizes in Wildwood

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft22,4002 tons2 tons
1,500 sq ft32,3003 tons2.5 tons
2,500 sq ft52,0004 tons5 tons
3,000 sq ft61,8005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,200 BTU/hr; a 350 sq ft living room needs about 7,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,700 BTU/hr.

Month by month in Wildwood

MonthAvg highCooling degree daysAC kWh
Jan69.9°F3860
Feb73.3°F6094
Mar77.3°F116182
Apr82.7°F228358
May88.1°F400629
Jun90.7°F507796
Jul91.1°F558877
Aug91.7°F569894
Sep89.7°F492773
Oct84.5°F326512
Nov77.3°F121190
Dec72.4°F67106

Aug alone uses 16% of the year's cooling energy. The unit runs the equivalent of 1,857 hours a year at full output.

Wildwood against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Leesburg, FL9 mi99°F4 tons
Lady Lake, FL9 mi99°F4 tons
Tavares, FL15 mi99°F4 tons
Groveland, FL17 mi99°F4 tons
Eustis, FL20 mi99°F4 tons
Minneola, FL22 mi99°F4 tons

Of 173 Florida cities here, Wildwood has the 66th highest cooling load. The range runs from Miami Shores at 36,500 BTU/hr to Plant City at 44,900.

Where Wildwood's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Leesburg Municipal Airport, 12 miles from the center of Wildwood at 68 ft above sea level. That is close enough that the station's summers are Wildwood's summers.

7 other cities use the same station and get the same climate inputs. The closest to Wildwood: Leesburg (9 mi away, 9.2 mi from the station), Lady Lake (9 mi away, 10.1 mi from the station), Tavares (15 mi away, 5 mi from the station), Groveland (17 mi away, 12.1 mi from the station), Eustis (20 mi away, 8.4 mi from the station). Wildwood is farther from the station than 5 of them.

The sun over Wildwood in late July

At 28.81°N, the noon sun on 21 July stands 81.6° above the horizon over Wildwood and the day runs 13 h 34 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.

19,031 people live in Wildwood, the 127th largest of the 173 Florida cities sized on this site. Coordinates used: 28.8058, -82.0073.

Wildwood AC sizing questions

What size AC does a 2,000 sq ft house in Wildwood, FL need?

About 4 tons, for a cooling load of 42,100 BTU/hr on a 99°F design day. That is one ton per 570 square feet in Wildwood's climate.

Is 20 BTU per square foot right for Wildwood?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Leesburg Municipal Airport. For a single room here, plan on 21.1 BTU/hr per square foot.

What does central AC cost to run in Wildwood?

About $838 a year: 5,469 kWh at SEER2 14.3 and 15.32¢ per kWh, over 11 cooling months.