ACSizeCheck

What size AC for West Carrollton, OH? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in West Carrollton needs

2.5 tons central AC or heat pump, about 29,800 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 41% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 805 square feet in this climate. For a single room, size by the room: 14.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Dayton Wright Brothers Airport (5.6 mi away). Jul is the hottest month, averaging a high of 85.9°F and a low of 65°F, with about 16 days a year at 90°F or more. That gives a design temperature of 90°F against 75°F inside.

What it costs to run

About 1,527 kWh a year at SEER2 14.3, or roughly $287 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in West Carrollton

Of the 29,800 BTU/hr, 10,800 comes through walls, roof and windows on a 90°F afternoon (36%), 13,000 is sun on the house (44%), 2,120 is four people and their appliances, and 3,900 is moisture the coil has to wring out of West Carrollton's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,920 BTU/hr before the moisture allowance.

Other house sizes in West Carrollton

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft16,1001.5 tons2 tons
1,500 sq ft23,0002 tons2.5 tons
2,500 sq ft36,7003.5 tons5 tons
3,000 sq ft43,5004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,900 BTU/hr.

Month by month in West Carrollton

MonthAvg highCooling degree daysAC kWh
Jan39.1°F00
Feb43°F00
Mar52.6°F23
Apr65.2°F1217
May74.8°F90125
Jun82.8°F228317
Jul85.9°F325451
Aug85.1°F288400
Sep78.8°F132183
Oct66.8°F2129
Nov53.8°F11
Dec42.9°F00

Jul alone uses 30% of the year's cooling energy. The unit runs the equivalent of 732 hours a year at full output.

West Carrollton against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Miamisburg, OH3 mi90°F2.5 tons
Kettering, OH6 mi90°F2.5 tons
Centerville, OH6 mi90°F2.5 tons
Springboro, OH8 mi90°F2.5 tons
Franklin, OH8 mi90°F2.5 tons
Dayton, OH8 mi90°F2.5 tons

Of 176 Ohio cities here, West Carrollton has the 59th highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.

Where West Carrollton's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Dayton Wright Brothers Airport, 5.6 miles from the center of West Carrollton at 953 ft above sea level. That is close enough that the station's summers are West Carrollton's summers.

9 other cities use the same station and get the same climate inputs. The closest to West Carrollton: Miamisburg (3 mi away, 3.6 mi from the station), Kettering (6 mi away, 8.3 mi from the station), Centerville (6 mi away, 5.2 mi from the station), Springboro (8 mi away, 2.1 mi from the station), Franklin (8 mi away, 4.5 mi from the station). West Carrollton is farther from the station than 4 of them.

The sun over West Carrollton in late July

At 39.67°N, the noon sun on 21 July stands 70.7° above the horizon over West Carrollton and the day runs 14 h 24 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

12,911 people live in West Carrollton, the 144th largest of the 176 Ohio cities sized on this site. Coordinates used: 39.6697, -84.2555.

West Carrollton AC sizing questions

What size AC does a 2,000 sq ft house in West Carrollton, OH need?

About 2.5 tons, for a cooling load of 29,800 BTU/hr on a 90°F design day. That is one ton per 805 square feet in West Carrollton's climate.

Is 20 BTU per square foot right for West Carrollton?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Dayton Wright Brothers Airport. For a single room here, plan on 14.9 BTU/hr per square foot.

What does central AC cost to run in West Carrollton?

About $287 a year: 1,527 kWh at SEER2 14.3 and 18.81¢ per kWh, over 5 cooling months.