ACSizeCheck

What size AC for Washington Court House, OH? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Washington Court House needs

2.5 tons central AC or heat pump, about 26,400 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 59% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 908 square feet in this climate. For a single room, size by the room: 13.2 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Washington Court House (0.3 mi away). Jul is the hottest month, averaging a high of 83.5°F and a low of 62.9°F, with about 12 days a year at 90°F or more. That gives a design temperature of 88°F against 75°F inside.

What it costs to run

About 1,083 kWh a year at SEER2 14.3, or roughly $204 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Washington Court House

Of the 26,400 BTU/hr, 9,360 comes through walls, roof and windows on a 88°F afternoon (35%), 13,000 is sun on the house (49%), 2,120 is four people and their appliances, and 2,000 is moisture the coil has to wring out of Washington Court House's summer air (8%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 24,480 BTU/hr before the moisture allowance.

Other house sizes in Washington Court House

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,4001.5 tons2 tons
1,500 sq ft20,4002 tons2.5 tons
2,500 sq ft32,5003 tons5 tons
3,000 sq ft38,5003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,900 BTU/hr.

Month by month in Washington Court House

MonthAvg highCooling degree daysAC kWh
Jan36°F00
Feb39.9°F00
Mar50.2°F11
Apr63.8°F57
May73°F6383
Jun80.7°F176230
Jul83.5°F257335
Aug82.3°F215281
Sep77.2°F99129
Oct65.7°F1317
Nov51.8°F11
Dec40.7°F00

Jul alone uses 31% of the year's cooling energy. The unit runs the equivalent of 586 hours a year at full output.

Washington Court House against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Wilmington, OH22 mi89°F2.5 tons
London, OH25 mi87°F2 tons
Circleville, OH27 mi90°F2.5 tons
Chillicothe, OH27 mi90°F2.5 tons
Xenia, OH29 mi90°F2.5 tons
Grove City, OH30 mi90°F2.5 tons

Of 176 Ohio cities here, Washington Court House has the 127th highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.

Where Washington Court House's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Washington Court House, 0.3 miles from the center of Washington Court House at 957 ft above sea level. That is close enough that the station's summers are Washington Court House's summers.

No other city in this set uses Washington Court House, so this sizing is Washington Court House's alone.

The sun over Washington Court House in late July

At 39.54°N, the noon sun on 21 July stands 70.9° above the horizon over Washington Court House and the day runs 14 h 23 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

14,446 people live in Washington Court House, the 121st largest of the 176 Ohio cities sized on this site. Coordinates used: 39.5379, -83.4278.

Washington Court House AC sizing questions

What size AC does a 2,000 sq ft house in Washington Court House, OH need?

About 2.5 tons, for a cooling load of 26,400 BTU/hr on a 88°F design day. That is one ton per 908 square feet in Washington Court House's climate.

Is 20 BTU per square foot right for Washington Court House?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Washington Court House. For a single room here, plan on 13.2 BTU/hr per square foot.

What does central AC cost to run in Washington Court House?

About $204 a year: 1,083 kWh at SEER2 14.3 and 18.81¢ per kWh, over 5 cooling months.