ACSizeCheck

What size AC for Warren, OH? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Warren needs

2 tons central AC or heat pump, about 25,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 64% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 935 square feet in this climate. For a single room, size by the room: 12.8 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Youngstown-Warren Regional Airport (7.5 mi away). Jul is the hottest month, averaging a high of 82.7°F and a low of 60.3°F, with about 8 days a year at 90°F or more. That gives a design temperature of 87°F against 75°F inside.

What it costs to run

About 826 kWh a year at SEER2 14.3, or roughly $155 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Warren

Of the 25,700 BTU/hr, 8,640 comes through walls, roof and windows on a 87°F afternoon (34%), 13,000 is sun on the house (51%), 2,120 is four people and their appliances, and 1,900 is moisture the coil has to wring out of Warren's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,760 BTU/hr before the moisture allowance.

Other house sizes in Warren

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,0001.5 tons2 tons
1,500 sq ft19,8001.5 tons2.5 tons
2,500 sq ft31,5003 tons5 tons
3,000 sq ft37,3003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,700 BTU/hr.

Month by month in Warren

MonthAvg highCooling degree daysAC kWh
Jan34.3°F00
Feb37.3°F00
Mar46.6°F11
Apr60.3°F79
May70.9°F4357
Jun78.8°F127166
Jul82.7°F211275
Aug81.1°F170222
Sep74.3°F6584
Oct62.1°F912
Nov49.6°F00
Dec38.7°F00

Jul alone uses 33% of the year's cooling energy. The unit runs the equivalent of 460 hours a year at full output.

Warren against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Niles, OH5 mi87°F2 tons
Youngstown, OH13 mi87°F2 tons
Sharon, PA16 mi87°F2 tons
Hermitage, PA19 mi87°F2 tons
Ravenna, OH23 mi90°F2.5 tons
Salem, OH23 mi86°F2 tons

Of 176 Ohio cities here, Warren has the 139th highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.

Where Warren's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Youngstown-Warren Regional Airport, 7.5 miles from the center of Warren at 1,167 ft above sea level. That is close enough that the station's summers are Warren's summers.

4 other cities use the same station and get the same climate inputs. The closest to Warren: Niles (5 mi away, 6.2 mi from the station), Youngstown (13 mi away, 10.8 mi from the station), Sharon (16 mi away, 9.1 mi from the station), Hermitage (19 mi away, 12.1 mi from the station). Warren is farther from the station than 1 of them.

The sun over Warren in late July

At 41.24°N, the noon sun on 21 July stands 69.2° above the horizon over Warren and the day runs 14 h 32 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

38,683 people live in Warren, the 34th largest of the 176 Ohio cities sized on this site. Coordinates used: 41.2396, -80.8160.

Warren AC sizing questions

What size AC does a 2,000 sq ft house in Warren, OH need?

About 2 tons, for a cooling load of 25,700 BTU/hr on a 87°F design day. That is one ton per 935 square feet in Warren's climate.

Is 20 BTU per square foot right for Warren?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Youngstown-Warren Regional Airport. For a single room here, plan on 12.8 BTU/hr per square foot.

What does central AC cost to run in Warren?

About $155 a year: 826 kWh at SEER2 14.3 and 18.81¢ per kWh, over 4 cooling months.