What size AC for Vernon Hills, IL? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Vernon Hills needs
2.5 tons central AC or heat pump, about 29,000 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 45% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 828 square feet in this climate. For a single room, size by the room: 14.5 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Chicago Palwaukee Airport (8.4 mi away). Jul is the hottest month, averaging a high of 84°F and a low of 65.8°F, with about 17 days a year at 90°F or more. That gives a design temperature of 89°F against 75°F inside.
What it costs to run
About 1,297 kWh a year at SEER2 14.3, or roughly $249 at Illinois's average residential rate of 19.23¢ per kWh. Cooling runs 5 months of the year here.
What drives the load in Vernon Hills
Of the 29,000 BTU/hr, 10,080 comes through walls, roof and windows on a 89°F afternoon (35%), 13,000 is sun on the house (45%), 2,120 is four people and their appliances, and 3,800 is moisture the coil has to wring out of Vernon Hills's summer air (13%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,200 BTU/hr before the moisture allowance.
Other house sizes in Vernon Hills
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 15,700 | 1.5 tons | 2 tons |
| 1,500 sq ft | 22,300 | 2 tons | 2.5 tons |
| 2,500 sq ft | 35,600 | 3 tons | 5 tons |
| 3,000 sq ft | 42,300 | 4 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,100 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,700 BTU/hr.
Month by month in Vernon Hills
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 31.9°F | 0 | 0 |
| Feb | 35.8°F | 0 | 0 |
| Mar | 46.7°F | 2 | 3 |
| Apr | 58.1°F | 6 | 8 |
| May | 69.5°F | 52 | 72 |
| Jun | 79.5°F | 181 | 252 |
| Jul | 84°F | 310 | 431 |
| Aug | 82°F | 263 | 365 |
| Sep | 75.3°F | 106 | 147 |
| Oct | 62.5°F | 13 | 18 |
| Nov | 48.5°F | 0 | 0 |
| Dec | 36.9°F | 0 | 0 |
Jul alone uses 33% of the year's cooling energy. The unit runs the equivalent of 640 hours a year at full output.
Vernon Hills against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Libertyville, IL | 3 mi | 86°F | 2 tons |
| Mundelein, IL | 4 mi | 89°F | 2.5 tons |
| Buffalo Grove, IL | 5 mi | 89°F | 2.5 tons |
| Lake Forest, IL | 5 mi | 89°F | 2.5 tons |
| Lake Zurich, IL | 7 mi | 89°F | 2.5 tons |
| Deerfield, IL | 7 mi | 89°F | 2.5 tons |
Of 225 Illinois cities here, Vernon Hills has the 126th highest cooling load. The range runs from Fox Lake at 24,900 BTU/hr to Granite City at 36,000.
Where Vernon Hills's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Chicago Palwaukee Airport, 8.4 miles from the center of Vernon Hills at 629 ft above sea level. That is close enough that the station's summers are Vernon Hills's summers.
22 other cities use the same station and get the same climate inputs. The closest to Vernon Hills: Mundelein (4 mi away, 12 mi from the station), Buffalo Grove (5 mi away, 4.3 mi from the station), Lake Forest (5 mi away, 8.3 mi from the station), Lake Zurich (7 mi away, 10.7 mi from the station), Deerfield (7 mi away, 4.1 mi from the station). Vernon Hills is farther from the station than 13 of them.
The sun over Vernon Hills in late July
At 42.23°N, the noon sun on 21 July stands 68.2° above the horizon over Vernon Hills and the day runs 14 h 38 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
27,002 people live in Vernon Hills, the 78th largest of the 225 Illinois cities sized on this site. Coordinates used: 42.2344, -87.9611.
Vernon Hills AC sizing questions
What size AC does a 2,000 sq ft house in Vernon Hills, IL need?
About 2.5 tons, for a cooling load of 29,000 BTU/hr on a 89°F design day. That is one ton per 828 square feet in Vernon Hills's climate.
Is 20 BTU per square foot right for Vernon Hills?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Chicago Palwaukee Airport. For a single room here, plan on 14.5 BTU/hr per square foot.
What does central AC cost to run in Vernon Hills?
About $249 a year: 1,297 kWh at SEER2 14.3 and 19.23¢ per kWh, over 5 cooling months.